FILE NO. SVM-10019

( RAS-12LKV-UL )

Turn off power supply once, and turn it on again.

 

 

YES

Is it possible to detect

 

NO

 

 

 

 

 

 

 

 

 

 

 

Does fan motor

 

 

 

 

 

 

 

 

 

 

 

 

DC 1V or more between

 

 

 

 

 

 

 

 

 

 

 

 

continue to operate?

 

 

 

5 + and 3 – of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

motor connector (CN31).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does check

NO

Does check connecting

 

NO

 

 

Reconnecting the

 

 

 

 

 

operation LED flash?

 

 

 

cable or power supply

 

 

 

 

 

 

in terconnection cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cord complely?

 

 

 

 

 

 

and terminal block

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does check

 

Does check 5V

 

 

 

 

 

5V at display unit?

 

 

 

 

 

 

 

at main P.C board?

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start to operate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace

 

 

 

 

 

 

 

 

indoor unit in cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

display unit

 

 

 

 

 

 

 

 

operation at airflow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

level “LOW”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Peplace indoor fan motor.

Does indoor fan operate?

YES

NO

 

Is it possible to detect

NO

DC 294–325V between

 

1

+ and 3 – of motor

 

 

 

connector (CN31).

 

Change airflow level to “HIGH”.

YES

(Motor connection condition)

NO

Is it possible to detect DC 15V

between 4 + and 3 – of

 

motor connector (CN31).

YES

Start to operate the indoor unit in except

heating operation. NO At this time, is it possible to

detect DC 1V or more between 5 + and 3 – of motor connector (CN31)?

YES

Turn off indoor unit and remove connector from motor. Then push [ ] button

on remote controller to stop flashing lamp on indoor unit.

Is it possible to detect

NO

DC 15V between 4

+

and 3 – of motor

 

 

connector (CN31).

 

 

YES

Turn off indoor unit and remove connector from motor. Then start to operate indoor unit with remote controller.

Start to operate the

 

 

indoor unit in except

 

 

heating operation.

 

NO

At this time, is it possible

to detect DC 1V or more

 

between 5 + and 3

 

of motor connector (CN31)? (Check this condition within 15 seconds after starting unit.)

Peplace main P.C. board.

YES

AB