3.30 BIOS SETUP 3 Tests and Diagnostics
Virtualization Technology
(e) Auto Power On
Use this option to set a time and date for automatic power on and enable or
disable the ring indicator feature. Alarm Date Option appears only when
Alarm Time is enabled.
Set the parameters for the Auto Power On (automatic power on) function and
the Wake-up on LAN in the “OPTIONS” window. To set the time, use Space
or BackSpace. Press ↓ to move the cursor to the right and ↑ to move the
cursor to the left when you set the date and time.
For the Alarm Time, set the time to turn on the power automatically. The
“second” cannot be set. When it is set to “Disabled”, the time to turn on
automatically is not set.
The Wake-up on LAN is a function to turn on the power automatically by the
call from the administrator. It can be set to “Enabled” only when “Built-in
LAN” is set to “Enabled”. To activate this function, use the AC adapter.
On Battery
The following settings can be changed when the Wake-up on LAN is Enabled.
Enabled Wake-up on LAN function whenoperating from the battery.
Disabled Wake-up on LAN function whenoperating from the battery
(Default).
NOTE: 1. Do not remove the AC adapter and battery pack at the same time when you use
this feature. If you do so, data saved by the resume function will be lost. You
must also reset this option.
2. When a password is set in Password Security, the system is in standby mode,
the Timer on function (Auto Power PN) is set and the system is booted,
“Password =” is displayed. When the password set in Password Security is
input, the computer returns to Windows from standby mode.
3. This function is effective only once, it is released after booting up.
Alarm Time = 00:00:00
Alarm Date Option = Disabled
Wake-up on LAN = Disabled
on Battery = Disabled
Critical Battery Wake-up = Enabled
O
PTIONS
TECRA A9(S5/P5/S200) Maintenance Manual (960-633) [CONFIDENTIAL] 3-95