Multifunctional Settings (continued)
OPTION Menu (continued)
Item |
|
| Description |
|
|
|
|
|
| |
|
|
|
|
|
|
| ||||
| Pressing the | (or the ENTER) button calls the SERVICE menu. |
|
|
|
| ||||
|
| SERVICE |
|
| ||||||
| SERVICE Menu |
|
|
|
|
|
| FANSPEED | NORMAL |
|
|
| / | buttons, and press the | (or the | AUTO ADJUST | ENABLE |
| |||
| Select an item using the | LENS TYPE | AUTO |
| ||||||
| ENTER) button to per form each function. : |
|
|
| LENS LOCK | TURN OFF |
| |||
|
|
|
| GHOST | 100 |
| ||||
| FANSPEED AUTO ADJUST LENS TYPE LENS LOCK GHOST FILTER MESSAGE | FILTER MESSAGE |
| |||||||
| : SELECT |
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| Select the fan speed level using the | / | buttons. : HIGH NORMAL | ||||||
| FANSPEED | The HIGH ups rotation speeds of fans, though. Please use this | ||||||||
| function in using a projector at highlands etc. |
|
|
|
| |||||
|
|
|
|
|
| |||||
|
| memo Note that the projector is noisier when the HIGH is selected. | ||||||||
|
|
|
|
|
| |||||
|
| Select the ENABLE or the DISABLE using the | / | buttons. : | ||||||
|
| ENABLE DISABLE |
|
|
|
|
|
| ||
|
| When the ENABLE is selected, detecting a signal change to a RGB | ||||||||
| AUTO | signal performs the automatic adjustment of the vertical position (V | ||||||||
| POSITION), the horizontal position (H POSITION), the clock phase | |||||||||
| ADJUST | (H PHASE) and the horizontal size (H SIZE). |
|
|
|
| ||||
|
| Depending on conditions, such as input image, signal cable to the unit, | ||||||||
|
| environment around the unit, etc., the automatic adjustment may not | ||||||||
|
| work correctly. In such a case, please choose DISABLE to disable the | ||||||||
|
| automatic adjustment, and adjust manually. |
|
|
|
|
| |||
|
|
|
|
|
| |||||
|
| Select the lens type currently used using the | / | buttons. : | ||||||
|
| AUTO 1 2 3 4 5 |
|
|
|
|
|
| ||
|
| Please select depending on the following. |
|
|
|
| ||||
|
| AUTO: automatically selects optimum mode. |
|
|
|
| ||||
SERVICE | 1: for a standard lens |
|
|
|
|
|
| |||
| LENS TYPE | 2: for a fixed short throw lens |
|
|
|
|
|
|
| 3: for a short throw lens |
|
|
| |||
| 4: for a long throw lens |
|
|
| |||
| 5: for a super long throw lens |
|
|
| |||
| memo This setting has an influence on the keystone distortion etc. | ||||||
| memo About the optional lens, ask your dealer. |
|
| ||||
|
|
|
| ||||
LENS LOCK | Select the TURN ON or the TURN OFF using the | / | buttons. : | ||||
TURN ON TURN OFF |
|
|
| ||||
| Selecting the TURN ON locks the adjustment of the lens shift, the zoom and the focus. | ||||||
|
|
|
| ||||
GHOST | 1. Choose a color element of ghost using the bottons | / | . | ||||
2. Adjust the chosen element using buttons | / | to disappear ghost. | |||||
| |||||||
|
|
|
| ||||
| Use the | / | button to set the timer for the interval to show the message for cleaning up the air filter. | ||||
| 100h 200h 300h TURN OFF 50h |
|
|
| |||
| After selecting "50h", "100h", "200h" or "300h", the message “REMINDER …” will | ||||||
| appear after the timer reaches the interval time set by this operation. Please | ||||||
FILTER | refer to the "FILTER TIME" item 41 and the table "Related message" 50 . | ||||||
When "TURN OFF" is chosen, the air filter cleaning message will not appear. Selecting "TURN | |||||||
MESSAGE | OFF" displays the message to call an attention to disabling the air filter cleaning message. |
•Please check and clean the air filter periodically, even if there is no message. If the air filter becomes blocked by dust or others, the internal temperature will rise, which could cause malfunction, or reduce the lifetime of the projector.
•It is recommended to choose "100h" in general. Please be careful with the operating environment of the projector and the condition of air filter, especially when "200h", "300h" or "TURN OFF" is chosen.
| Select the EXECUTE using the | button to reset the OPTION menu items. : | |
RESET | EXECUTE CANCEL |
| |
The items of the OPTION menu are collectively returned to the initial setting. Note that | |||
| |||
| the items “VOLUME”, “LAMP TIME”, “FILTER TIME” and “SERVICE” are not reset. |