Troubleshooting (continued)

Phenomena That May Easily Be Mistaken For Machine Defects (continued)

Phenomenon

Cases not involving a machine defect

Reference

pages

 

 

 

 

 

 

The signal cables are not correctly connected.

16, 17

 

Correctly connect the connection cables.

 

 

 

 

 

Pictures are

The volume is adjusted to an extremely low level.

27, 41

Adjust the VOLUME to a higher level.

displayed,

 

 

The sound is muted.

 

but no sounds

27

are heard.

Press the MUTE button to restore the sound.

 

 

 

 

 

The audio input is not correctly selected when the child window

30

 

is displayed.

 

Correctly select the audio input.

 

 

 

 

 

The lens cap is attached.

12, 23

 

Remove the lens cap.

 

 

 

 

 

Sounds are

The signal cables are not correctly connected.

16, 17

heard,

Correctly connect the connection cables.

 

but no pictures

 

 

The brightness is adjusted to an extremely low level.

31

are displayed.

Adjust the BRIGHT to a higher level using the menu function.

 

 

 

 

 

 

The screen is blanked.

27

 

Press the BLANK button to return to the input signal screen.

 

 

 

 

 

Video screen

The FREEZE function is working.

28

display freezes.

Press the FREEZE button to restore the screen to normal.

 

 

 

 

Colors have a

Color settings are not correctly adjusted.

 

faded- out

Perform picture adjustments by changing the COLOR BAL R,

32

appearance, or

COLOR BAL G, COLOR BAL B, COLOR and/or TINT settings, using

 

Color tone is poor.

the menu functions.

 

 

 

 

 

The brightness and/or contrast are adjusted to an extremely low

 

 

level.

31

 

Adjust the BRIGHT and/or CONTRAST settings to a higher level

 

 

Pictures appear

using the menu function.

 

 

 

dark.

The WHISPER function is working.

31

 

Select the NORMAL to the item WHISPER in the MAIN menu.

 

 

 

 

 

 

The lamp is approaching the end of its product lifetime.

45, 46

 

Replace the lamp.

 

 

 

 

 

 

Either the focus and/or horizontal phase settings are not

 

 

properly.

24, 34

Pictures appear

Adjust the focus using the focus buttons, and/or H PHASE using the

 

menu function.

 

blurry.

 

 

 

 

 

 

 

The lens is dirty or misty.

48

 

Clean the lens by referring to the section “Caring For The Lens”.

 

 

 

 

 

Input signal

The INPUT dial is set between the click points.

 

changes with no

24

Turn the INPUT dial and set it at a click point.

operation.

 

 

 

 

 

 

54

Page 54
Image 54
Toshiba TLP-SX3500 Phenomena That May Easily Be Mistaken For Machine Defects, Color settings are not correctly adjusted