Performance

Water-Cooled

Data

52 Ton

 

 

 

 

Table PD-29. SCWF/SIWF 52 - Economizer Full Capacity - 20,800 cfm

Entering Water Temp

Entering Air

 

 

45 F

 

 

55 F

 

EDB

EWB

Flow

Total

Sensible

LWT

Total

Sensible

LWT

F

F

gpm

MBh

MBh

F

MBh

MBh

F

 

 

130

546.6

489.7

53.4

341.8

341.8

60.3

 

62

156

570.0

499.6

52.3

350.4

350.4

59.5

 

 

182

588.4

507.5

51.5

356.6

356.6

58.9

 

 

130

694.3

417.0

55.7

402.7

307.8

61.2

75

67

156

737.5

434.2

54.5

424.2

315.4

60.4

 

 

182

771.2

447.8

53.5

441.7

321.7

59.9

 

 

130

887.8

350.3

58.7

576.6

241.3

63.9

 

72

156

945.5

371.6

57.1

616.7

254.8

62.9

 

 

182

990.6

388.5

55.9

647.8

265.4

62.1

 

 

130

598.2

586.1

54.2

427.0

427.0

61.6

 

62

156

616.2

604.1

52.9

437.6

437.6

60.6

 

 

182

630.1

618.1

51.9

445.4

445.4

59.9

 

 

130

707.0

530.2

55.9

442.3

430.2

61.8

80

67

156

744.9

545.4

54.5

458.6

436.1

60.9

 

 

182

774.8

557.5

53.5

471.5

440.8

60.2

 

 

130

885.8

459.3

58.6

577.3

350.6

63.9

 

72

156

943.2

480.9

57.1

615.2

363.4

62.9

 

 

182

988.1

498.1

55.9

645.6

373.7

62.1

 

 

130

679.1

679.1

55.4

512.1

512.1

62.9

 

62

156

696.3

696.3

53.9

524.8

524.8

61.7

 

 

182

708.9

708.9

52.8

534.0

534.0

60.9

 

 

130

736.6

649.9

56.3

513.8

513.8

62.9

85

67

156

769.0

662.9

54.9

526.6

526.6

61.8

 

 

182

794.5

673.3

53.7

535.8

535.8

60.9

 

 

130

888.9

569.1

58.7

597.7

466.2

64.2

 

72

156

943.3

589.5

57.1

629.7

477.0

63.1

 

 

182

986.2

606.0

55.8

655.5

485.8

62.2

Table PD-30. SCWF/SIWF 52 - Economizer Low Capacity - 20,800 cfm

Entering Water Temp

Entering Air

 

 

45 F

 

 

55 F

 

EDB

EWB

Flow

Total

Sensible

LWT

Total

Sensible

LWT

F

F

gpm

MBh

MBh

F

MBh

MBh

F

 

 

130

363.7

361.8

50.6

238.6

238.6

58.7

 

62

156

378.3

367.7

49.9

245.6

245.6

58.1

 

 

182

390.1

372.6

49.3

250.9

250.9

57.8

 

 

130

461.2

297.3

52.1

264.6

226.1

59.1

75

67

156

488.3

307.6

51.3

277.6

230.6

58.6

 

 

182

509.6

315.8

50.6

288.6

234.5

58.2

 

 

130

589.2

236.9

54.1

382.8

167.2

60.9

 

72

156

625.0

249.6

53.0

406.6

174.9

60.2

 

 

182

653.2

259.8

52.2

425.4

181.1

59.7

 

 

130

413.9

413.9

51.4

298.2

298.2

59.6

 

62

156

426.4

426.4

50.5

306.9

306.9

58.9

 

 

182

435.8

435.8

49.8

313.5

313.5

58.4

 

 

130

464.9

385.4

52.2

299.4

286.4

59.6

80

67

156

489.3

394.7

51.3

309.0

295.9

59.0

 

 

182

509.2

402.3

50.6

316.7

303.6

58.5

 

 

130

588.0

323.6

54.0

381.6

254.0

60.9

 

72

156

623.6

336.3

53.0

405.2

261.7

60.2

 

 

182

651.7

346.4

52.2

423.9

267.8

59.7

 

 

130

473.1

473.1

52.3

357.9

357.9

60.5

 

62

156

487.2

487.2

51.2

368.3

368.3

59.7

 

 

182

497.9

497.9

50.5

376.1

376.1

59.1

 

 

130

488.4

480.9

52.5

358.6

358.6

60.5

85

67

156

508.5

488.6

51.5

369.0

369.0

59.7

 

 

182

524.8

494.9

50.8

376.9

376.9

59.1

 

 

130

586.7

410.2

54.0

391.6

344.3

61.0

 

72

156

622.2

422.8

53.0

411.1

350.7

60.3

 

 

182

650.2

432.9

52.1

427.1

355.9

59.7

50

PKG-PRC002-EN

Page 50
Image 50
Trane PKG-PRC002-EN manual 52 Ton, Table PD-30. SCWF/SIWF 52 Economizer Low Capacity 20,800 cfm

PKG-PRC002-EN specifications

The Trane PKG-PRC002-EN is a groundbreaking packaged rooftop unit designed to meet the diverse needs of commercial and industrial spaces. This model showcases Trane’s commitment to innovation, energy efficiency, and reliability, making it a preferred choice for HVAC professionals and building owners alike.

One of the main features of the PKG-PRC002-EN is its high-efficiency design. This unit leverages advanced technologies to minimize energy consumption while ensuring optimal cooling and heating performance. Its efficient compressor, coupled with enhanced heat exchangers, significantly reduces operating costs and energy bills, aligning with today’s sustainability goals.

The PKG-PRC002-EN features a robust and durable construction, which translates to enhanced longevity and reduced maintenance requirements. Designed for ease of installation, the unit is compact and lightweight, facilitating seamless retrofitting and integration into existing systems. Furthermore, its accessible service panels allow for straightforward maintenance and repairs, thus minimizing downtime and service disruptions.

Equipped with Trane's advanced control technology, the PKG-PRC002-EN offers precise temperature management, ensuring consistent comfort across different zones within a building. The intuitive controls enable users to program schedules and adjust settings based on their specific needs, enhancing comfort while maximizing efficiency.

The model also incorporates advanced filtration options, improving indoor air quality by effectively reducing pollutants and allergens. This focus on health and safety is essential, especially in commercial settings where air quality can significantly impact occupant well-being and productivity.

Another notable characteristic of the PKG-PRC002-EN is its low noise levels during operation, which is essential for maintaining a conducive indoor environment in workplaces, retail spaces, or educational institutions. The unit's design minimizes sound transmission, creating a more pleasant atmosphere for occupants.

In summary, the Trane PKG-PRC002-EN is a highly efficient, reliable, and user-friendly rooftop unit that combines advanced technology with robust construction. Its energy-saving features, superior air quality options, and focus on quiet performance make it an excellent choice for modern commercial HVAC applications, ultimately contributing to sustainable building practices and enhanced occupant comfort.