Trane TCONT803AS32DA, TCONT802AS32DA 2H/1C heat pump, Pub. No. 18-HD25D19-3, 69-1790-3

Models: TCONT803AS32DA TCONT802AS32DA

1 20
Download 20 pages 51.81 Kb
Page 6
Image 6
(2H/1C heat pump).

TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION

 

 

 

 

 

HEAT PUMP

 

 

 

 

 

 

Y2

 

 

 

1

 

RC

 

 

 

F

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

X2

 

 

 

 

 

O

 

 

 

W1

 

 

 

 

 

Y

 

 

2

S1

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

T

S2

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VARIABLE

R

BK

O

G

YLO

Y

W1

W2

B/C

SPEED

TWO STAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FURNACE

INDOOR

OUTDOOR

1

2

R

Y

O

BR/X2

BR(T)

 

B

 

 

 

HEAT PUMP

 

 

 

 

O.D. SECTION

 

 

 

OR BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(SINGLE STAGE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO POWER SUPPLY

(3 PH

 

 

 

 

 

 

FACTORY INSTALLED JUMPER.

PER LOCAL CODES

ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR REMOTE SENSOR. WIRES MUST HAVE A

CABLE SEPARATE FROM THE THERMOSTAT CABLE.

M24201

Fig. 13. Typical hookup of single-stage heat pump with two stage variable speed gas furnace