TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION

Table 4. Installer Setup Menu. (Continued)

 

 

 

 

 

 

 

 

 

Factory Setting

 

Other Choices

 

 

Installer

 

 

 

 

 

Select

Setup

 

 

 

 

 

Number

Option

Description

Options

Description

Comments

Deadband

0310

2 thru 9

Heating and cooling

3

Heating and cooling setpoints

Shown only if

 

 

 

setpoints can be set

 

can be set no closer than 3°F

automatic

 

 

 

no closer than chosen

 

(1.5°C).

changeover is

 

 

 

value:

 

 

selected.

 

 

 

2—2°F (1°C)

 

 

The deadband is

 

 

 

3—3°F (2°C)

 

 

restricted to the range

 

 

 

4—4°F (2.5°C)

 

 

of 5 to 9 if ISU 0380 is

 

 

 

5—5°F (3°C)

 

 

set to

 

 

 

6—6°F (3.5°C)

 

 

dehumidification

 

 

 

7—7°F (4°C)

 

 

droop control.

 

 

 

8—8°F (4.5°C)

 

 

 

 

 

 

9—9°F (5°C)

 

 

 

 

 

 

 

 

 

 

Temperature

0320

0

Temperature is

1

Temperature is displayed in °C.

Indication

 

 

displayed in °F.

 

 

 

Scale

 

 

 

 

 

 

Daylight

0330

1

Daylight savings

0, 2

0—daylight savings is

Set to 0 in areas that

Savings

 

 

enabled (use through

 

disabled.

do not follow daylight

 

 

 

2006 and for areas

 

2—daylight savings is enabled

savings.

 

 

 

that do not use the

 

(start using in 2007, for areas

 

 

 

 

new 2007 DST

 

that use the new 2007 DST

 

 

 

 

calendar).

 

calendar).

 

Remote

0340

0

No remote

1-3

1—outdoor temperature

Defaults and Options

Temperature

 

 

temperature sensor

 

sensor for display only.

depend on System

Sensor

 

 

 

 

2—outdoor temperature

Type selection.

(Outdoor or

 

 

 

 

sensor for system control,

Indoor Temperature

Indoor)

 

 

 

 

used for select heat pump

Sensor uses an

 

 

 

 

 

systems. (See Special Heat

averaging network

 

 

 

 

 

Pump Features section for

and does not include

 

 

 

 

 

more details.)

on-board sensor.

 

 

 

 

 

3—indoor temperature sensor

 

Heat Pump

0350

0

No compressor

15, 20,

15°F (-9.5°C)

Default depends on

Compressor

 

 

lockout.

25, 30,

20°F (-6.5°C)

other selections.

Lockout

 

 

 

35, 40,

25°F (-4°C)

Shown if Outdoor

 

 

 

 

45

30°F (-1°C)

Temperature for

 

 

 

 

 

35°F (1.5°C)

control is selected.

 

 

 

 

 

40°F (4.5°C)

 

 

 

 

 

 

45°F (7°C)

 

 

 

 

 

 

 

 

Heat Pump

0360

0

No heat pump

40, 45,

40°F (4.5°C)

Shown if electric is

Auxiliary

 

 

auxiliary lockout.

50, 55,

45°F (7°C)

chosen for backup

Lockout

 

 

 

60

50°F (10°C)

heat source and

 

 

 

 

 

55°F (13°C)

outdoor temperature

 

 

 

 

 

60°F (15.5°C

sensor for control is

 

 

 

 

 

 

selected.

Indoor

0380

0

No indoor

1

1—dehumidification droop

Available on models

Dehumidifica-

 

 

dehumidification

 

control.

with humidity sensor.

tion Control

 

 

control.

 

 

 

Furnace Filter

0500

0

Furnace filter change

1-6

1—10 run time days

Run time based on

Change

 

 

reminder off.

 

2—30 run time days

call for fan.

Reminder

 

 

 

 

3—60 run time days

 

 

 

 

 

 

4—90 run time days

 

 

 

 

 

 

5—120 run time days

 

 

 

 

 

 

6—365 run time days

 

Humidifier

0510

0

Humidifier pad

1-3

1—90 calendar days

Pad

 

 

replacement reminder

 

2—180 calendar days

 

Replacement

 

 

off.

 

3—365 calendar days

 

Reminder

 

 

 

 

 

 

Pub. No. 18-HD25D19-3

 

69-1790—3

14

Page 14
Image 14
Trane TCONT803AS32DA, TCONT802AS32DA installation instructions Deadband 0310