Deployment & Installation

RU Installation and Antenna Alignment

Link Test

Ensure the RU’s default Opmode is “ON,” and that all configuration parameters are correct.

Reboot the radio. Once the radio enters Opmode “ON,” the authentication process will occur with the MU, and the two radios will begin to associate. From the MU side, use the Link Control page to assess the quality of the link.

Enter a duration time for the RF Link Loopback / Speed Test. Click the “loopback test” button. The test will execute and report the success rate (packets sent and received) after the duration period.

A similar test can be performed from the command line interface via the command ru speedtest. Example:

#> ru speedtest

Some traffic may be dropped during testing.

Pkt Len = 1760 bytes, File Size = 10 MBytes, 5958 pkts

Press [space] then [enter] to stop

5.+++*

4.+++*

3.+++*

2.+++*

1.+++*

0.+++*

[M RxGood] 10486080 bytes [R RxGood] 10486080 bytes --> 16750 ms 10016 Kbps

Success.

#>