Deployment & Installation

Installation

Standard Mounting

Alternative Mounting

U p / D o w n

T i l t

Up/Down Tilt

4 X M u s t B e l o o s e n e d f o r U p / D o w n T i lt

Figure 8: Mounting Articulation

Proper mounting of the radio includes consideration for grounding. Please note that if the radio is attached to a metal pole that is earth- grounded, no other grounding is necessary. If the radio is not earth-grounded via the mounting bracket, you must attach a grounding wire to the grounding stud on the back of the radio as in the adjacent diagram.

Figure 9: Grounding Example

Cabling and Weather Considerations

Shielded twisted pair Cat-5 cable is recommended for all installations. The shield within the Cat-5 cable does not need to be grounded if the radio itself is grounded. It is important to consider that most Cat-5 cable will deteriorate over time if exposed to the weather (especially direct sunlight). It is recommended that installers place all Cat-5 cables inside conduit. Plastic conduit is sufficient. If metal conduit is used, it is not necessary to use shielded Cat-5 cable.

Trango Broadband Wireless — TrangoLINK-10 User Manual Rev. E 3.0

page 20

Page 24
Image 24
Trango Broadband TrangoLink-10 user manual Cabling and Weather Considerations, Standard Mounting Alternative Mounting