Trango Broadband TrangoLink-10 user manual Same as updateflash

Models: TrangoLink-10

1 33
Download 33 pages 46.31 Kb
Page 31
Image 31

Command Set Summary

Command

Description

OFF

ON

Remark

ru reboot

reboot Remote Radio

 

se

 

 

ru speedtest [<packet length>

perform speedtest

 

se

default:

<file size>]

<pkt len> = 64..1760 bytes

 

 

<pkt len> = 1760 bytes

 

<file size> = 10..100 Mbytes

 

 

<file size> = 10 MBytes

ru sysinfo

request Remote’s system information

 

se

 

 

ru testrflink [<packet length>]

perform RF loopback test testrflink

 

se

default:

 

<pkt len> = 64..1760 bytes

 

 

<pkt len> = 1760 bytes

reboot

reboot unit

se

se

 

 

remarks [<str>]

string length should be 1 to 28 characters

se

se

 

 

reset [<all 0…n>]…

reset radio to the firmware default

se

 

 

 

 

n# = 0..2

 

 

 

 

 

Master:

 

 

 

 

 

0 - Channel Table, Active Channel = 1 h,

 

 

 

 

 

Switches, and Remarks

 

 

 

 

 

1 - TX Power = Max, RF Threshold = -90

 

 

 

 

 

dBm, Target RSSI = -60 dBm, MIR

 

 

 

 

 

Downstream = 10000 kbps, Upstream =

 

 

 

 

 

10000 kbps

 

 

 

 

 

2 - SNMP Community String (Read/Write)

 

 

 

 

 

= (public/private)

 

 

 

 

 

Remote:

 

 

 

 

 

0 - Channel Table, Active Channel = 1 h,

 

 

 

 

 

Switches, and Remarks

 

 

 

 

 

1 - TX Power = Max, RF Threshold = -90

 

 

 

 

 

dBm

 

 

 

 

 

2 - SNMP Community String (Read/Write)

 

 

 

 

 

= (public/private)

 

 

 

 

rfrxth <ism> <-90 -85 -80 -

specify RF RX Threshold

se

se

default = -90 for both

75 -70 -65>

 

 

 

band

rfrxthreshold …

same as “rfrxth

se

se

 

 

rssi

display current RX RSSI

se

 

 

 

save

same as “updateflash

se

se

 

 

save mm

same as “updateflash mainimage

se

se

 

 

save ss

same as “updateflash systemsetting

se

se

 

 

set defaultopmode [<on off>]

set or display default Opmode

se

se

 

 

set httpport [<port #>]

set or display HTTPD port number

se

se

default = 80

set mir [<downstream,

set or display MIR

se

se

 

 

kbps>][<upstream, kbps>]

<kps> = 100..10000

 

 

 

 

set rssitarget <dB>

set Target RSSI Threshold

se

se

 

 

 

It must be -45 to –75, and +5 dB higher

 

 

 

 

 

than RF RX Threshold.

 

 

 

 

set snmpcomm [<read write>]

display or assign SNMP community string

se

se

 

 

set telnetport [<port #>]

specify telnet port, <port #> = 1..65534

se

se

default = 23

ssrssi <ch #> <v h>

display RSSI on the current channel

se

 

 

 

survey <ism> <time, sec> <hv>

spectrum analysis of entire RF band

se

 

 

 

sw 0 [<on off>]

set sw #0 – packet filter for

se

se

default = on

 

broadcast/multicast

 

 

 

 

sw 1 [<on off>]

set sw #1 – HTTPD service

se

se

default = on

sw 2 [<on off>]

set sw #2 – Auto scan Master signal

se

se

default = on

sw 3 [<on off>]

set sw #3 – Auto power leveling Remote

se

se

default = on

 

Unit

 

 

 

 

sysinfo

display system configuration

se

se

 

 

temp

display current temperature

se

se

 

 

 

 

 

 

 

 

Trango Broadband Wireless — TrangoLINK-10 User Manual Rev. E 3.0

 

 

page 27

Page 31
Image 31