Tripp Lite SMART2200RM2U, SMART2600RM2U, SMART3000RM2UP, SMART3000RMXL2U owner manual Basic Operation

Models: SMART2200RMXL2U SMART3000RMXL2U SMART2200RM2U SMART3000RM2UP SMART2200RMXL2UP SMART2600RM2U

1 64
Download 64 pages 15.18 Kb
Page 11
Image 11

Basic Operation continued

INPUT Icon: Indicates that the 3-digit value displayed is the Input Voltage.

OUTPUT Icon: Indicates that the 3-digit value displayed is the Output Voltage.

LOAD Icon: Displayed in two modes:

1.Displayed in conjunction with the % icon and 3-digit value to indicate the load percentage.

2.Displayed in conjunction with KWH/Day and 3-digit value to indicate daily power consumption.

3.Both the LOAD icon and Warning icon will flash to indicate an overload.

BATT Icon: Displayed in two modes:

1.BATT icon (displayed in conjunction with % icon and 3-digit value) indicates the Battery Capacity %.

2.BATT icon is shown with TEST icon to indicate self test mode or control mode.

% Icon: Indicates units of %.

TEST Icon: Displayed in conjunction with BATT icon to indicate that the UPS is performing a self-test.

RUNTIME Icon: Displayed in conjunction with the MIN icon and 3-digit value to indicate Runtime in minutes.

MIN Icon: Indicates units of minutes.

1.Displayed in conjunction with RUNTIME icon and 3-digit value to indicate battery runtime in minutes.

2.Displayed in conjunction with the 3-digit value (reporting “LCD”) to indicate the minimum brightness.

VWA Icon: This is a multipurpose icon which indicates units of Volts, VA, Watts, or Amps (V, VA, W, or A will be shown).

K Icon: Displayed in conjunction with the W to indicate Kilowatts. It is also used in conjunction with the WH and /DAY icons to indicate Kilowatt Hours per Day.

H and /DAY Icons: Displayed in conjunction with “K” and “W” icons to indicate Kilowatt Hours per day (KWH/DAY).

Sensitivity Icon: Displayed to set the AC input line sensitivity setting. Sensitivity settings available are 100% (Normal = Full Counter clockwise POT), 50% (half delay), and 25% (full delay = full Clockwise POT).

SCROLL Icon: When enabled, the display will automatically cycle through each DISPLAY mode of the LCD once per two-second interval. If a button is pressed while Scroll Mode is enabled, the scroll function will pause for 10 seconds to allow the user to manually make menu selections before resuming scroll.

11

12-12-037-93-3088-B.indb 11

12/26/2012 3:47:31 PM

Page 11
Image 11
Tripp Lite SMART2200RM2U, SMART2600RM2U, SMART3000RM2UP, SMART3000RMXL2U, SMART2200RMXL2UP owner manual Basic Operation