1LCD Screen: Provides detailed information about operating conditions, UPS system settings and more. See the next page for a description of the LCD symbols.

2LINE LED: This green LED illuminates continuously to indicate the utility-supplied AC line voltage of the AC supply circuit is nominal. It will flash if the line voltage is outside the nominal range (either too low or too high), but still acceptable. User action is not required when the LED flashes; the UPS system continuously and automatically filters AC line power to provide equipment with pure sine wave AC power, regardless of brownout or overvoltage conditions. If this LED is off, then AC line voltage is not present (blackout) or is at an unacceptable level, and the UPS system will provide connected equipment with power from its battery system.

3Bypass LED: If an internal fault or overload occurs, the LED will flash repeatedly to show that connected equipment will receive filtered AC line power, but will not receive battery power during a blackout. In this case, contact Tripp Lite for service.

4Parallel Redundancy LED: This green LED illuminates when the UPS system is operating in parallel redundancy mode.

5Economy Mode LED: This amber LED illuminates when the UPS system is operating in economy mode.

6Fault LED: This red LED illuminates when UPS system experiences a fault or other abnormal condition. If the condition persists after restarting the UPS system, refer to Section 9 – Troubleshooting.

7“ON” Button: This button controls these separate functions:

UPS System Power ON

To turn on the UPS system, press this button for approximately one second until the UPS system beeps, then release the button.

Buzzer Silence

To silence the UPS system’s buzzer, press this button and hold it until the UPS system beeps, then release the button.

UPS System Cold Start

To use the UPS system as a stand-alone power source when AC power is unavailable (i.e. during a blackout), press this button and hold it until the UPS system beeps, then release the button. See Section 6-4 – Battery Mode Startup for more information.

8“OFF” Button: This button turns off power to the UPS system’s output. Press this button and hold it until the UPS system beeps, then release it. The battery will continue to charge and the fan will continue to operate even when the output is off. To turn the UPS system off completely, including the battery charger, turn off the UPS system’s utility AC input breaker after pressing the “OFF” switch.

9“Enter” Button: This button confirms changes to the UPS system settings.

10“Function” Button: This button allows access to special functions.

11Previous/Change Setting Button: This button returns to the previous page or changes the UPS system settings, depending on the context.

12Next Button: This button goes to the next page.

10

Page 10
Image 10
Tripp Lite SU10KRT3/1X owner manual Standard Operation, Control Panel Features, UPS System Power on, Buzzer Silence

SU10KRT3/1X specifications

The Tripp Lite SU10KRT3/1X is a robust and efficient 10kVA UPS (Uninterruptible Power Supply) designed to meet the power management needs of critical electronic equipment. This industrial-grade UPS is ideal for safeguarding servers, telecommunications equipment, and networking hardware, providing the reliability necessary in today's tech-dependent world.

One of the standout features of the SU10KRT3/1X is its ability to deliver pure sine wave output, which ensures that connected devices receive a stable and clean power supply. This is especially crucial for sensitive electronics, including servers and other IT infrastructure components that require a consistent power source to maintain peak performance and operational integrity.

The UPS boasts a comprehensive input voltage range, making it adaptable to various power conditions. With an output power factor of 0.9, the SU10KRT3/1X maximizes the power available for connected devices, providing efficient power usage that ultimately lowers operational costs. This UPS also features an automatic voltage regulation (AVR) system that stabilizes voltage fluctuations, offering an additional layer of protection against surges and brownouts.

Another significant characteristic of the Tripp Lite SU10KRT3/1X is its modular design, featuring hot-swappable batteries that allow for easy maintenance without shutting down connected equipment. This feature minimizes downtime and enhances reliability, ensuring that critical systems remain functional even during maintenance activities.

The LCD display provides real-time status information, including input and output voltage, battery status, and load levels. This user-friendly interface allows IT administrators and technicians to monitor the UPS easily and respond quickly to any potential issues.

Compatibility is another area where the SU10KRT3/1X excels. It is equipped with multiple communication options, including USB, RS-232, and optional SNMP capability, enabling seamless integration with monitoring systems and ensuring effective communication with connected devices.

Tripp Lite has backed the SU10KRT3/1X with a solid warranty and exceptional customer support, assuring users of the product's reliability and performance. As organizations increasingly rely on technology, the SU10KRT3/1X serves as a trustworthy solution for maintaining consistent power availability, ultimately contributing to business continuity and efficiency.