Check Spay Gun and Nozzle Extension
Examinethe hose connection to the spray gun and make sure it is secure. Test the trigger by pressing it and making sure it "springs back" into place when you releaseit. Put the trigger lock in the ON position and test the trigger. You should not be ableto press the trigger.
Nozzle Maintenance
A pulsing sensation felt while squeezingthe spray gun trigger may be caused by excessive pump pressure. The principal causeof excessivepump pressure is a spray tip clogged or restricted with foreign materials, such as dirt, etc. To correct the problem, immediately clean the spray tip following these instructions:
1.Shut off engine and turn off water supply.
2.ALWAYSpoint spray gun in a safe direction and squeezespray gun trigger to release retained high water pressure.
WARNING
The high pressure stream of water that this equipment produces can cut through skin and its
possible amputation.
_ nderlying tissues, leading to serious injury and Spray gun traps high water pressure, even when
engine is stopped and water is disconnected, which can cause injury.
•Keephighpressurehoseconnectedto pumpandspraygun whilesystemis pressurized.
. ALWAYSpointspraygunin safedirectionandsqueezespray guntrigger,to releasehighpressure,everytimeyou stop engine.Engagetriggerlockwhennotin use.
3.Remove spray tip from end of nozzleextension.
4.Use a small paperclip to free any foreign material clogging or restricting spray tip (A).
5.Remove nozzleextension from spray gun.
6.Using a garden hose, remove additional debris by back flushing water through nozzleextension. Backflush between30 to 60 seconds.
7.Reinstall spray tip into nozzle extension.
8.Reconnect nozzleextension to spray gun.
9.Make sure garden hose is connected to water inlet. Checkthat high pressure hose is connected to spray gun and pump. Turn on water.
10.Engagetrigger lock on spray gun and start engine following instructions How to Start Your Pressure Washer.
11.Test pressure washer by operating with each quick connect spray tip.
Purchasean