28 m a i n ten a n ce and troubleshooting

is s u e

p os si ble cause(s)

resolution

 

 

 

F1: Blower Running

o Oven power interrupted.

o Verify wall circuit breaker is on.

Status Bad

 

 

Reset breaker and then power the

 

 

 

oven back on.

 

 

 

o Place the oven into Off State for two

 

 

 

(2) minutes, disconnect the plug for

 

 

 

minimum of two (2) minutes, re-plug

 

 

 

in the oven and and press the oven

 

 

 

on soft key.

 

 

 

F2: Cook

o Oven power interrupted.

o Verify wall circuit breaker is on.

Temperature Low

 

 

Reset breaker and then power oven

 

 

 

back on.

 

o Air nozzles on the top of the

o Open oven door and verify the air

 

 

cook cavity are clogged.

nozzles on the top of the cook cavity

 

 

 

are clean and not clogged.

 

o Oven door is out of alignment.

o Open and close the door several times

 

 

 

and verify oven door is closed. Reset

 

 

 

high-limit located in the bottom left

 

 

 

corner of the oven rear wall.

 

o Defective heater.

o Call Customer Service.*

 

o Blower motor not running.

o Perform self-test (page 26) and call

 

 

 

Customer Service.*

 

o Oven not fully warmed-up.

o Repeat warm-up and allow oven to

 

 

 

idle for five (5) minutes.

 

 

 

 

F3: Magnetron

o

Microwave circuit defective.

o Perform self-test (page 26) and call

 

 

 

Current Low

 

 

Customer Service.*

F4: Door Monitor

o

Oven door switches are out of

o Perform self-test (page 26) and call

 

 

 

Defective

 

order.

Customer Service.*

F5: Magnetron Over

o Blockage of cool air into

o Check for paper towels or anything

Temperature

the oven.

that may be obstructing cool air into

 

o Rear cooling fan exhaust

the oven.

 

o Check rear fan to see if it is free of

 

guard is clogged.

debris. Clean as required.

Page 36
Image 36
Turbo Chef Technologies Tornado 2 owner manual F1 Blower Running