24 and 16 Port Smart Switch II – User Manual

Page 9

These option modules are installed as described on page 6.

The following plug-in fibre modules are available as field installable accessories for this switch: -

 

Product

Part Number

100

Fx Module with SC multimode connectors

0-1591094-0

100

Fx Module with ST multimode connectors

0-1591095-0

100

Fx Module with SC singlemode connectors

0-1591096-0

Dual Gigabit Sx Multimode SC connectors

0-1591097-0

Dual Gigabit Lx Singlemode SC connectors

0-1591098-0

Dual Gigabit Copper Module 1000BaseT

2-1591019-0

Table 1 - Uplink Option Ports

Optical Link Wavelength

The 100 Fx optional modules operate at the 1310nm optical wavelength. The Gigabit Lx Singlemode module operates at 1310nm and the Gigabit Sx multimode module operates at 850nm optical wavelength.

Optical Link Calculations

The maximum distance between any two fibre optic devices is determined by a number of factors including optical link loss, the type and number of patch cords and joints in the link, the launch power of the transmitter and the sensitivity of the receiver. These variables make calculating the maximum working distance between two units quite difficult and so it is best to design networks using optical loss budgets rather than using just working distance.

Dual Gigabit 1000BaseT copper module

The RJ-45 will auto-negotiate 100Base-TX and Gigabit 1000T connections. Support for Auto MDI/MDIx is also provided.

It should be noted that Gigabit 1000T (1000Mbps) connection must use Cat-6 or Cat5-E twisted cable pair cable. If use cat-5 cable is used then support 100Mbps link speed is available only. The available link distance is up to 100Meters.

Product Number 0-1591093-x 0-1591047-x

Issue 1

© Tyco Electronics 2005

 

Page 9
Image 9
Tyco Electronics 0-1591093-X Optical Link Wavelength, Optical Link Calculations, Dual Gigabit 1000BaseT copper module