![Condenser Cleaning](/images/new-backgrounds/71370/7137027x1.webp)
To defrost:
1.Turn unit off.
2.Remove all products from the interior and prop the door in an open position (2 in. (5 cm) minimum).
3.Allow the frost to completely melt naturally. Clean the interior and all removed components using a mild non- abrasive detergent and warm water solution applied with a soft sponge or
4.Dampen a soft sponge or
5.When the interior is dry, turn unit on.
Condenser Cleaning
Interval - Every Three Months
To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.
WARNING
Disconnect electric power to the unit before cleaning the condenser.
WARNING
DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
IMPORTANT
DO NOT use any type of cleaner on the condenser unit.
Model 29R
1. Disconnect power to the unit.
2 |
1 |
ULIN_0197_A |
Figure 11
2.Remove the control knob (Figure 11, 1) by pulling it straight out, away from grille.
3.Remove two screws from grille (Figure 11, 2) and save.
4. Remove grille and grille cap from unit.
1 |
ULIN_0153_A |
Figure 12
5.Clean the condenser coil (Figure 12, 1) using a using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.
| 2 |
1 | ULIN_0198_A |
Figure 13
6.Make sure grille cap is behind grille in slots provided in grille (Figure 13, 1) before attaching grille to unit, and secure but do not overtighten both grille screws (Figure 13, 2).
7.Reinstall the control knob (Figure 11, 1).
8.Reconnect power to the unit.
Model 1115R
1.Disconnect power to the unit.
1
3
2
ULIN_0155_A
Figure 14
2. Loosen the two screws (Figure 14, 1) completely.
NOTE: Screws are held in the grille by
3.Remove grille (Figure 14, 2) and grille cap (Figure 14, 3) from unit.
14 | 1115R, 1175R, 29R, 1175BEV |