Condenser Cleaning

To defrost:

1.Turn unit off.

2.Remove all products from the interior and prop the door in an open position (2 in. (5 cm) minimum).

3.Allow the frost to completely melt naturally. Clean the interior and all removed components using a mild non- abrasive detergent and warm water solution applied with a soft sponge or non-abrasive cloth. NOTE: DO NOT use any solvent-based or abrasive cleaners. They will discolor or damage the interior.

4.Dampen a soft sponge or non-abrasive cloth in clean water and wipe down the cabinet interior and removed components to remove any detergent residue. Rinse the sponge or cloth in clean water and repeat as necessary until the cabinet and components are clean.

5.When the interior is dry, turn unit on.

Condenser Cleaning

Interval - Every Three Months

To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.

Interval - Every Three MonthsWARNING

Disconnect electric power to the unit before cleaning the condenser.

Disconnect electric power to the unit before cleaning the condenser.WARNING

DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.

IMPORTANT

DO NOT use any type of cleaner on the condenser unit.

Model 29R

1. Disconnect power to the unit.

2

1

ULIN_0197_A

Figure 11

2.Remove the control knob (Figure 11, 1) by pulling it straight out, away from grille.

3.Remove two screws from grille (Figure 11, 2) and save.

4. Remove grille and grille cap from unit.

1

ULIN_0153_A

Figure 12

5.Clean the condenser coil (Figure 12, 1) using a using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.

 

2

1

ULIN_0198_A

Figure 13

6.Make sure grille cap is behind grille in slots provided in grille (Figure 13, 1) before attaching grille to unit, and secure but do not overtighten both grille screws (Figure 13, 2).

7.Reinstall the control knob (Figure 11, 1).

8.Reconnect power to the unit.

Model 1115R

1.Disconnect power to the unit.

1

3

2

ULIN_0155_A

Figure 14

2. Loosen the two screws (Figure 14, 1) completely.

NOTE: Screws are held in the grille by o-ring retainers, and will not come free of the grille.

3.Remove grille (Figure 14, 2) and grille cap (Figure 14, 3) from unit.

14