U-Line 29R Electronic Control Panel, Temperature Display Selection, Checking Product Temperature

Models: 1115R 1175R 1175BEV 29R

1 32
Download 32 pages 21.34 Kb
Page 8
Image 8
Electronic Control Panel

Electronic Control Panel

1

2

3

4

5

 

 

 

ULIN_0074_A

Figure 5

Models 1115R, 1175R and 1175BEV

The electronic control with digital display (Figure 5) is configured to show a single temperature continuously. This set-point temperature is a base number used by the controller to maintain the temperature zone in your unit. The factory default set-point is 38°F. This set-point temperature is used as a gauge if further temperature adjustments are required.

Model 1175BEV has a DISPLAY OFF mode available through the control panel. This mode allows you to control whether the display (Figure 5, 3) will be ON or OFF whenever the door is closed. The button sequence that follows will switch between both modes:

1.Press and hold the WARMER button (Figure 5, 4), and simultaneously within five seconds press the ON/OFF button (Figure 5, 2) three times.

2.The display will be either visible or dark when the door is closed.

3.To return to the previous mode, repeat Step 1.

Temperature Display Selection

U-Line products supplied for 110 VAC operation have temperatures displayed in a default Fahrenheit (°F) configuration (Figure 5, 3). Models supplied for 220 VAC operation have temperatures displayed in a default Celsius (°C) configuration.

The display can easily be adjusted for either type of temperature display. Press and hold the LIGHT button (Figure 5, 1) and simultaneously within five seconds press the COOLER button (Figure 5, 5) three times to change the display as desired.

Temperature Display

To display actual temperature:

1.Press the WARMER button (Figure 5, 4) for five seconds. The display (Figure 5, 3) will indicate the actual temperature.

2.After approximately 10 seconds, the set point temperature will return to the display.

Checking Product Temperature

ULIN_0093_A

Figure 6

IMPORTANT

U-Line recommends a set temperature of 38°F on all refrigerators.

To check the actual product temperature in your unit, insert an accurate thermometer into a plastic (non- breakable) bottle that is partially filled with water. Tighten the bottle cap securely (Figure 6).

Place the bottle in the desired area for 24 hours. Refrain from opening the unit during the testing period. After 24 hours, check the temperature of the water. If required, adjust the temperature control in a small increment (See

ADJUSTING TEMPERATURE).

Factors which affect the internal temperatures of the cabinet include:

Temperature setting.

Ambient temperature where installed.

The number of times and length of time a door is opened and closed.

The amount of time the internal light is illuminated. (This affects primarily product on top rack or shelf.)

Installation in direct sunlight or near a heat source.