PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

Electronic display is blank and

Unit is in blackout/Sabbath mode

Exit blackout/Sabbath mode (not Star K certified)

interior light is off with door open.

(not Star K certified).

(See OPERATION).

 

 

 

Electronic display is blank and

A display function has changed.

Touch and hold the WARMER button and touch and

interior light is on with door open.

 

release the ON/OFF button three times, then release the

 

 

temperature button. The display should become visible.

 

 

 

Electronic display shows repeating,

A factory control mode has been

Touch and hold the warmer temperature button and

randomly flashing symbols and

inadvertently entered.

touch and release the LIGHT button three times, then

partial characters.

 

release the temperature button to exit the factory

 

 

control mode. The set-point temperature should now

 

 

be displayed.

 

 

 

Electronic display shows:

A factory control mode has been

Repeatedly touch the WARMER button to advance any

0, 1 to 16, or 99.

inadvertently entered.

number shown to 99 and touch and release the LIGHT

 

 

button. The set-point temperature should now be

 

 

displayed.

 

 

 

Electronic display shows one or

The unit is displaying an error code.

Record the error code(s) displayed and call for service.

more of the following:

 

 

E1, E2, E4, E5, E6.

 

 

 

 

 