U-Line manual Leveling, Models 1175R and 1175BEV, 1115R, 1175R, 29R, 1175BEV

Models: 1115R 1175R 1175BEV 29R

1 32
Download 32 pages 21.34 Kb
Page 15
Image 15
Models 1175R and 1175BEV

1

ULIN_0156_A

Figure 15

4.Clean the condenser coil (Figure 15, 1) using a using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.

1

2

3

ULIN_0157_A

Figure 16

5.Make sure grille cap (Figure 16, 1) is behind grille in slots (Figure 16, 2) provided in grille before attaching grille to unit, and secure, but do not overtighten both grille screws (Figure 16, 3).

6.Reconnect power to the unit.

Models 1175R and 1175BEV

1. Disconnect power to unit.

2

1

 

 

ULIN_0158_A

Figure 17

2. Loosen the two screws (Figure 17, 1) completely.

NOTE: Screws are held in the grille by o-ring retainers, and will not come free of the grille.

3.Remove grille from unit.

4.Clean the condenser coil (Figure 17, 2) using a using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.

 

1

 

2

3

ULIN_0159_A

Figure 18

5.Place the hook-hinge (Figure 18, 1) located on the rear bottom side of the grille onto the front lip (Figure 18, 2) of the unit base. Swing the grille up into position, and align the screw holes on the grille to the grille screw hole on the cabinet.

6.Secure, but do not overtighten both grille screws (Figure 18, 3).

7.Reconnect power to unit.

Leveling

It is important that units equipped with adjustable feet are level, for proper door and ice maker (if equipped) operation.

NOTE: Models 29R DO NOT have leveling feet. These models MUST be placed on a level surface to operate properly.

To level units with adjustable feet:

1

ULIN_0041_A

Figure 19

1.Use a level to check the levelness of the unit from front to back and from side to side. Level should be placed along top edge and side edge as shown (Figure 19).

1115R, 1175R, 29R, 1175BEV

15

Page 15
Image 15
U-Line manual Leveling, Models 1175R and 1175BEV, 1115R, 1175R, 29R, 1175BEV