United States Stove 1602G, 1802G Domestic Hot Water Coil Kit - Optional, Ussc

Models: 1602G 1802G

1 20
Download 20 pages 7.72 Kb
Page 15
Image 15
DOMESTIC HOT WATER COIL KIT - OPTIONAL

DOMESTIC HOT WATER COIL KIT - OPTIONAL

2

1

ACCESS

PANEL

3

This Furnace will accept the installation of a Domestic Hot Water Coil Kit. The U.S. Stove kit is a 1124 Water Coil and it may be purchased from your local dealer.

1.Remove the access panel on the rear of the furnace enclosure.

2.With a utility knife, cut away a section of the insulation (if equipped) directly behind the access panel.

3.Remove the cover plate from the rear of the furnace firebox.

4.Place one nut on each end of the water coil and thread each nut up to the end of the threads on the coil.

5.Insert the coil through the holes from the inside of the firebox. Install a gasket, washer and nut onto each end of the water coil. Tighten the nuts down securely to in- sure an air tight seal.

The installation is now ready to be plumbed to your exist- ing hot water system. Choose one of the three methods described in the Hot Water Coil instructions.

6.Remove knockouts from the access panel and re-attach to the furnace enclosure.

5

1.NUT DR6 - 6” DRAFT REGULATOR KIT - OPTIONAL KIT

2.WASHER

3.GASKET

REAR WALL OF

Manual background FIREBOX

4

DOMESTIC HOT WATER

COIL

6

Manual background TURN INSIDE NUTS UP

TO END OF THREADS

Have a qualified plumber connect your domestic hot water pipe to the coil with the appropriate fittings.

DR6 - 6” DRAFT REGULATOR KIT - OPTIONAL KIT

In the unlikely event that your furnace “overfires” (a con- dition evidenced by elbows, stove pipes, and connec- tors glowing red in appearance or otherwise discoloring), then your installation is subject to excessive draft created by either a chimney too tall or too great in diameter in conjunction with its height, or some other factor of an indeterminate cause. In this event, you should install a barometric draft regulator. Such installation will preclude any over-firing and/or any hazardous consequences of potential overfiring.

Barometric draft regulators are generally available where you purchased your stove or may be ordered directly from United States Stove Company at a nominal charge.

USSC

15