INSTALLATION CODES

Installation must be performed in accordance with state and local codes, or, in the absence of local codes, with the following: National Fuel Code, ANSI Z223.1 (latest edition) the National Electric Code (NEC) ANSI/NFPA 70 (latest edition). Canada: CAN/CGA B149.1, CAN/CGA B149.2 and CSA C22.2 No. 1 (latest edition).

UNPACKING

Immediately after unpacking, check thoroughly for any possible shipping damage. If the POWERMAXtm is found to be damaged, contact the carrier immediately (15 days maximum). Be sure to save all the packaging materials for shipper’s inspection.

LOCATING THE POWERMAXtm BOOSTER HEATER

Locate the POWERMAXtm so that all required clearances are maintained. The appliance must be located in an area that is clear and free from combustible materials, including gasoline and other flammable or corrosive liquids and vapors. The booster heater should not be located in an area where water leakage could cause damage to adjacent areas or areas below the unit. If this is not possible, the booster heater should be installed in an adequate catch pan (preferably stainless steel) that is properly drained. If appliance is installed on carpeting, it must be installed on a wood or metal panel extending beyond the full width and depth of the appliance by at least 3 inches (76.2mm) in each direction. The booster heater should be installed with no more than five feet of pipe between the 180- degree outlet and the dishwasher rinse valve (as specified by NSF-5). If the piping exceeds five feet, the optional circulation return kit must be installed to maintain proper temperature at the dishwasher rinse valve. The POWERMAXtm may be installed up to 150 feet from the dishwasher when using the circulation kit. Call factory for details.

INSTALLATION CLEARANCES

Minimum clearances from combustible or non-combustible construction -

8” (fire 2”, service 8”) Left side, 2” Right side, 6” Back, 0” Top, 24” Front (minimum for service). The four 6” adjustable legs allow the unit to be leveled on uneven floors by screwing the feet up or down as needed.