Vermont Casting 3399, 3369 Radiance Direct Vent/Natural Vent Gas Heater, All Models, 20004188

Models: 3369 3390 3399 3360 3225 3354 3350 3232

1 44
Download 44 pages 26.46 Kb
Page 32
Image 32
Models 3352, 3354, 3390 thru 3399 (RF Models) Only

Radiance Direct Vent/Natural Vent Gas Heater

Pilot Hood

Index

Marks

Pilot Bracket

Center

Plunger

Blue - NGRed - LP

Motor Top Cap

Valve

LOCAL

FP1037b

CO105

Fig. 60 Remove pilot hood. (Your pilot may have a different appearance.)

 

Pilot

 

Orifice

 

CO106b

Fig. 61

Remove pilot orifice.

NOTE: Be sure burner leg remains at a 90° angle to firebox base after conversion.

Models 3352, 3354, 3390 thru 3399 (RF Models) Only

1.Follow procedure for pilot type 2 to replace pilot orifice.

2.Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 26, Fig. 49)

3.Remove motor top cap. Depress and turn center plunger until arrow points to correct screw. Red for LP and Blue for NG. NOTE: Plunger will “snap” into NG position when arrow is close to blue screw. It will not “snap” at LP (Red) position. (Fig. 62)

4.Insure manifold pressure remains between 3.2” - 3.5” w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the manifold pressure, for NG, using a torque #10 key turn the blue screw clockwise to increase the manifold pressure. Turn the screw counterclockwise to de- crease the pressure. Use the red screw to adjust LP.

5.Replace motor top cap.

Fig. 62 Depress and turn center plunger.

All Models

1.Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner.

NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base. (Fig. 63) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit.

2.Place conversion label on valve.

3.Reinstall the right and left log bracket assembly.

4.Reinstall the rear log bracket.

5.Replace logs.

6.Replace glass and stove front.

Conversion is complete.

Left Burner Leg

Injector Orifices

90°

ST353a

Fig. 63 Remove and replace injector orifices.

3232

20004188

Page 32
Image 32
Vermont Casting 3369 Radiance Direct Vent/Natural Vent Gas Heater, Models 3352, 3354, 3390 thru 3399 RF Models Only