Vermont Casting manual DVRT41 Direct Vent Gas Fireplace, Total angular variation, 10006740

Models: DVRT41

1 48
Download 48 pages 31.74 Kb
Page 16
Image 16
Total angular variation

DVRT41 Direct Vent Gas Fireplace

The maximum number of 90° elbows per side wall installation is three (3). (Fig. 2)

If a 90° elbow is fitted directly on top of the fireplace flange the maximum horizontal vent run before the termination or a vertical rise is 36” (914mm). (Fig. 27)

 

 

7'

A

10'

(178 cm) B

 

(254 cm)

 

 

 

A + B = 17’

8'

 

(518cm) Max.

3 x 90°Manual background Elbows Manual backgroundManual background

3 x 90°

Elbows

FP1176

(244 cm)

V584-201

Fig. 29 Maximum vent run with elbows.

In Figure 28 & 29, dimension A plus B must not be greater than 17’ (5.2m)

The maximum number of 45° elbows permitted per

side wall installation is two (2). These elbows can

Fig. 26

Maximum three (3) 90° elbows per installation.

 

36"

 

(914mm)

 

Max.

 

36"

 

(914mm)

 

Max.

 

FP1177

Fig. 27

Maximum horizontal run with no rise.

If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36” (914mm). (Fig. 28 & 29) This does not apply if the 90° elbows are used to increase or redirect a vertical rise. (Fig. 26)

Example: According to the vent graph (Page 13) the maximum horizontal vent length in a system with a 7¹⁄₂’ (2.3m) rise is 20’ (6m) and if a 90° elbow is required in the horizontal vent it must be reduced to 17’ (5.2m).

AB

A + B = 17’ (Max.)

(5.2m)

7’6"

(2.3m)

FP1178

Fig. 28 Horizontal run reduction.

16

be installed in either the vertical or horizontal run.

For each 45° elbow installed in the horizontal run,

the length of the horizontal run MUST be reduced

by 18” (457mm). This does not apply if the 45°

elbows are installed on the vertical part of the vent

system.

The maximum number of elbow degrees in a sys-

tem is 270°. (Fig. 30) Example:

 

Elbow 1

=

90°

 

Elbow 2

=

45°

 

Elbow 3

=

45°

 

Elbow 4

=

90°

Total angular variation

=

270°

 

1 + 2 + 3 + 4 = 270°

1

 

 

1

 

 

 

2

 

 

2

 

 

 

3

 

 

3

 

 

 

4

 

 

4

 

 

 

 

 

 

FP1180

Fig. 30

Maximum elbow usage.

 

 

 

 

10006740

Page 16
Image 16