Framing And Finishing

Framing And Finishing

Check fireplace to make sure it is lev- elled and properly positioned.

To mount the appliance:

1.Choose the location.

2.This unit comes with four (4) flanges pre-mounted on both sides of the fireplace to allow two different drywall thicknesses to be used. Flange “A” is for 1/2” drywall while flange “B” is for 5/8” drywall.

3.Bend the desired flanges out 90° on both sides of the fireplace. Slide the fireplace into the framed opening until the flanges contact the front surfaces of the framing. Level the unit and secure it firmly in place.

Flange

Drywall

Flange Location for

Position

Depth

Desired Drywall Depth

A

1/2” / 13mm

 

B

5/8” / 16mm

 

A

B

 

 

 

FP1539

Fig. 5 Drywall flange location.

 

DVRT41Direct Vent Gas Fireplace

Gas Specifications

 

 

 

MAX.

MIN.

 

 

GAS

INPUT

INPUT

MODEL

FUEL

CONTROL

B.T.U.H

B.T.U.H.

DVRT41RN

Natural Gas

Millivolt Hi/Lo

36,000

25,200

DVRT41RP

Propane

Millivolt Hi/Lo

36,000

27,000

DVRT41RFN

Natural Gas

Comfort Control

36,000

25,200

DVRT41RFP

Propane

Comfort Control

36,000

27,000

DVRT41EN

Natural Gas

24 Volt Hi/Lo

36,000

25,200

DVRT41EP

Propane

24 Volt Hi/Lo

36,000

27,000

 

 

 

 

 

Gas Inlet and Manifold Pressures

 

Natural

LP (Propane)

Minimum Inlet Pressure

5.5” w.c.

11.0” w.c.

Maximum Inlet Pressure

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

 

 

 

DVRT41

Certified To

ANSI Z21.88-2002/CSA 2.33-2002

Vented Gas Fireplace Heater

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

Final Finishing

Noncombustible materials such as brick or tile can be extended over the edges of the face of the fireplace. Do not cover the window frame assembly, any vent, louvre assembly top or louvre assembly bottom. If a Trim Kit is to be installed, brick and tile will have to be installed flush with the side of this appliance.

Gas Line Installation

When purging gas line the front glass must be removed.

The gas pipeline can be brought in through the right side of the appliance. Knockouts are provided at convenient locations to allow for the gas pipe installa- tion and testing of any gas connection.

The gas line connection can be made with properly tinned 3/8" copper tubing, 1/2" rigid pipe or an approved flex connector. Since some municipalities have additional local codes, it is always best to consult your local authority and the CSA-B149.1installation codes. For USA installations consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.

10006740

7

Page 7
Image 7
Vermont Casting DVRT41 manual Framing And Finishing, Gas Specifications, Gas Inlet and Manifold Pressures, High Elevations