| Motor Top Cap | |
Center |
|
|
| |
Plunger |
|
|
| |
Blue - |
| LOCAL |
| |
NG | Red - LP | FP1037b | ||
|
| |||
Fig. 65 | Depressd and turn center plunger. |
| ||
| Manifold |
| Pilot Location |
|
| Assembly | Burner Pan |
|
|
|
|
|
|
Manifold Mounting
Screw
Orifice | CO101a |
|
Fig. 66 Remove manifold assembly.
Rear Burner Orifice:
Refer to Conversion Kit
Orifice Chart
Front Burner Orifice:
Refer to Conversion Kit
Orifice Chart
CO124 |
|
|
Fig. 67 Burner orifice replacement. |
| |
Shutter | Burner Pan |
|
Retaining |
|
|
Screw |
|
|
Air Shutter | Front View |
|
| CO103 | |
|
| |
Fig. 68 Remove air shutter from burner pan. |
|
10.Reinstall manifold mounting screw.
NOTE: It is not necessary to remove the pilot tube for conversion.
11.Loosen pilot hood turning counterclockwise using a 7/16” wrench. (Fig. 69)
12.Remove pilot orifice with needlenose pliers. (Fig. 70)
13.Install conversion pilot orifice.
14.Reinstall pilot hood. Be sure to align pilot hood with index marks.
DVRT41Direct Vent Gas Fireplace
|
| Pilot Hood |
Index |
|
|
Marks |
| |
Pilot |
| |
Bracket | CO105 | |
Fig. 69 | Remove pilot hood. |
|
|
| Pilot Orifice |
|
| CO106 |
Fig. 70 | Remove pilot orifice. |
|
15.Turn the gas supply valve and gas valve on and test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. Apply water/soap solution with brush only - do not over apply. NEVER test with an open flame.
16.Follow procedure on rating plate to light the pilot. Check for leaks.
17.Turn main burner on and check for leaks. 18.Install logs. Refer to Page 24 for proper log place-
ment.
Installation complete.
10006740 | 37 |