Chateau™

Hearth

A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace. The hearth cannot exceed 1¹⁄₂” (38mm) in height from bottom of fireplace for ease of door accessibility. (Fig. 5)

Cold climate installation recommendation: When installing this unit against a non- insulated exterior wall or chase, it is

mandatory the outer walls be insulated to conform to applicable insulation codes.

If a vapor barrier is used it can not come into contact with fireplace.

Framing and Finishing

1.Choose the unit location.

2.The unit is shipped with four (4) nailing flanges mounted to the sides near the front corners. (Fig. 5)

3.Frame the fireplace with a header across the top of the standoff. (Fig. 6) It is very important to allow for the finished wall face along with marble, tiles or any other noncombustible face finish material desired when setting the depth of the framing.

Valve Box

Assembly

Bend

Line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3"

 

 

 

 

 

 

 

 

 

3"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(76 mm) Min.

 

(76 mm) Min.

1���"

 

(38 mm)

 

Max. Hearth Height

FP1775

Fig. 5 Nailing flanges.

4.Attach the fireplace nailing flanges to the frame as shown in Figure 5.

5.The gas components are located in the control panel assembly attached to the right side of the unit. (Fig. 5)

3" (76mm)

3"

FP1560

(76mm)

 

Fig. 6 Fireplace framing.

6.The U-channel located on the top of the unit as well as the nailing flanges on the sides that were men- tioned in Step 1, are designed to accommodate non- combustible board (recommended Dura-Rock). They are positioned 1” (25mm) back from the face of the unit. NOTE: The U-channel depth can be adjusted by loosening the hex nut inside the channel.

If marble, tile or any other noncombustible decora- tive face finish material is desired, a 3” (76 mm) wide noncombustible board (recommended Dura-Rock) is to be nailed to the nailing flanges on both sides of the unit. Also, 12” (305 mm) of noncombustible board is to be nailed to the front face of the U-chan- nel and the top framing member above the standoff.

Combustible material can then be brought to the outside edges of the noncombustible board installed earlier. Any noncombustible decorative face finish could be brought to the sides and top of the unit and can cover the framing and sheet rock. If a decora- tive facing is not desired, then the noncombustible boards must be double thickness and brought flush with the face of the unit.

Final Finishing

Noncombustible materials such as brick or tile may be brought to the edges of the face of the appliance.

6

20011956

Page 6
Image 6
Vermont Casting DVT44 installation instructions Hearth, Framing and Finishing, Final Finishing