Vermont Casting Install ON/OFF Switch, Vermont Castings Jefferson Vent Free Gas Heater, 20003447

Models: JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 JUVSR 3096, JUVSM 3096 JUVSR, JUVSM, 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112

1 22
Download 22 pages 59.18 Kb
Page 10
Image 10
Install ON/OFF Switch

Vermont Castings Jefferson Vent Free Gas Heater

2.Disconnect the snapstat module from the leads inside the snapstat bracket. (Fig. 8)

3.Bend open the snapstat bracket. use your fingers or needle nose pliers to remove the black plastic grommet from the bracket. Discard the grommet and bracket.

Pinch Grommet to Remove

Snapstat

Bracket

Snapstat

Module

ST468

Fig. 8 Remove snaptstat and grommet from bracket.

4.Secure the snapstat to the upper middle of the inner shroud. (Fig. 9) NOTE: The snapstat location may be reached through the front of the stove between the top and the firebox or you may loosen the four screws holding the rear shroud in place. Be sure to secure shroud back into place before operation.

5.Connect the two wires to the two snapstat extension leads attached to the inner shroud. You may coil excess wire up inside the rear shroud.

Snapstat

ST346a

Fig. 9 Attach snapstat to inner shroud.

6.Route the rheostat control switch and wire forward under the stove. (Fig. 10) Use the wire tie to secure the fan and rheostat wire harnesses together to the tubing under the heater.

 

Rheostat

Retaining Nut

 

Control Knob

ST347a

Fig. 10 Attach rheostat to control panel. Valve may look different.

MOTOR

 

 

BLK

 

BLK

BLK

 

 

 

 

 

 

SNAPSTAT

 

 

BLK

WHT

WHT

GRN

ON/OFF

 

RHEOSTAT

 

 

 

 

ST236

Fig. 11

Fan wiring diagram.

 

Install ON/OFF Switch

(R Models only)

The switch assembly parts are found in the parts bag.

1.Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Fig. 12)

2.Run wires down back of stove, under bottom of rear shroud to valve.

3.Attach wires to valve terminals. (Fig. 13)

Switch

Existing Holes

Assembly

 

Screws

ST315

 

Fig. 12 Attach switch assembly to rear shroud.

TH

TP

TPTH

ST228

Fig. 13 Attach switch wires to valve.

10

20003447

Page 10
Image 10
Vermont Casting JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 Install ON/OFF Switch