Vermont Casting Clearance Requirements, Minimum Clearances to Combustible Materials, 20003447

Models: JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 JUVSR 3096, JUVSM 3096 JUVSR, JUVSM, 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112

1 22
Download 22 pages 59.18 Kb
Page 5
Image 5
Clearance Requirements

Vermont Castings Jefferson Vent Free Gas Heater

Clearance Requirements

Minimum Clearances to

Combustible Materials

Maintain clearance, (empty space), between combus- tible materials and the heater as specified below for the appropriate firebox shell being installed.

D

B Minimum Clearances toA Hearth RequirementsW A R N I N G C

 

 

 

ST101

 

 

 

A: Mantel Trim

12” (305mm)

B: Side Wall/Trim

4” (102mm)

C: Rear Wall

4” (102mm)

D: Max. Mantel Depth

12” (305mm)

Alcove Clearances

B

 

B

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ST103

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A: Ceiling

 

 

27¹⁄₂” (699mm)

B: Side Wall

 

 

4” (102mm)

C: Rear Wall

 

 

4” (102mm)

D: Max. Alcove Depth

 

 

48” (1219mm)

Fig. 2 Minimum wall clearances

 

 

A

 

 

 

 

B

 

 

 

 

C

 

 

 

S

D

 

 

 

 

 

 

 

T

 

E

Wall

 

 

 

 

U

 

 

F

 

 

V

 

 

 

 

 

 

 

W

 

G

 

 

 

X

 

 

 

 

 

 

 

 

Y

 

 

 

 

FP599a

 

Mantel

 

 

Mantel from

Ref.

Shelf Depth

Ref.

 

Stove Top

A

12” (305mm)

S

 

12” (305mm)

B

10” (254mm)

T

 

10” 254mm)

C

8” (203mm)

U

 

8” (203mm0

D

6” (152mm)

V

 

6” (152mm)

E

4” (102mm)

W

 

4” (102mm)

F

2” (51mm)

X

 

2” (51mm)

G

1” (25mm)

Y

 

1” (25mm)

Hearth Requirements

The JUVS must be installed on rigid flooring. If the appliance is installed on any combustible surface other than wood flooring, such as carpet or tile, a metal or wood panel must be installed to extend the full length and width of the unit.

W A R N I N G

Do not install this heater in a bathroom or bedroom.

Installation of this heater must conform with Local Codes or in the absence of Local Codes, with the National Fuel Gas Code, ANSI Z223.1.

This heater creates warm air currents. These currents move heat to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater where impurities in the air such as tobacco smoke exist, may discolor walls.

Do not use a blower insert, heat exchanger insert or other accessory not approved with this heater.