Vermont Casting JUVSR 3096, JUVSM 3096 Troubleshooting, W A R N I N G, Condition, Possible Cause

Models: JUVSR & JUVSM 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112 JUVSR 3096, JUVSM 3096 JUVSR, JUVSM, 3095, 3096, 3097, 3100, 3101, 3102, 3105, 3106, 3107, 3110, 3111, 3112

1 22
Download 22 pages 59.18 Kb
Page 15
Image 15
Troubleshooting

Vermont Castings Jefferson Vent Free Gas Heater

Troubleshooting

Follow these procedures in the order presented.

W A R N I N G

TURN OFF HEATER AND ALLOW TO COOL

COMPLETELY BEFORE SERVICING.

CONDITION

POSSIBLE CAUSE

SOLUTION

 

 

 

No spark at pilot when Ignitor is operated.

1.Ignition Electrode is disconnected from ignition wire, broken or incorrectly positioned.

2.Ignitor wire is broken.

3.Bad Piezo Ignitor.

1.Inspect and re-connect, replace or repair as necessary.

2.Replace wire.

3.Replace Piezo Ignitor.

The Ignitor Electrode sparks, but Pilot does not light.

1.Gas supply is turned off or supply line shut-off valve is closed.

2.Control Knob is not in PILOT position.

3.Control Knob not pressed in while in PILOT position.

4.Air present in gas lines.

5.Inlet supply pressure is not within correct settings.

6.Other conditions that should be identified only by a qualified gas technician.

1.Turn on gas supply or open supply line shut-off valve.

2.Turn Control Knob to PILOT.

3.Press Control Knob in while in the PILOT position.

4.Continue holding in Control Knob and repeat ignition procedure until air is bled from the lines.

5.Call local gas supplier. Adjust inlet supply pressure to specification: NG; 5.5” w.c.-14.0”w.c. LP; 11.0” w.c.-14.0”w.c.

6.Call qualified gas technician.

Pilot/Main Con- trol

ADJ

PILOT

 

TPTH

 

TP

 

TH

OFF

CONDITIONPOSSIBLE CAUSEON

PILOT

Piezo Ignitor

Regulator

L

O H

 

 

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Piezo Igni-

Pilot/Main Control

tor

 

LO SOLUTION

Manual backgroundManual backgroundManual background PILOT

OFF

HI

ST120

Fig. 24 JUVS Honeywell Control Valve Assembly.

Fig. 25 JUVS SIT Control Valve Assembly.

20003447

15

Page 15
Image 15
Vermont Casting JUVSR 3096, JUVSM 3096 Troubleshooting, Vermont Castings Jefferson Vent Free Gas Heater, W A R N I N G