APPENDIX B. THE INFRARED MUG/CUP SENSOR

Hot Drink Center Set-Up Manual

APPENDIX B. THE INFRARED MUG/CUP SENSOR

The infrared mug/cup sensor can sense the presence of a mug or cup without using moving parts.

Indicator Light

The sensor is equipped with an indicator light. This light will help you get the best results from the infrared mug/cup sensor.

Under these conditions, the indicator light should be off:

Machine door open

Cup station in place

No cup in the station

If it is on, it is indicating improper cup station alignment or excessive sensor sen- sitivity.

Testing the light...Under these conditions:

Machine door closed

Cup station in place

No cup in the station

Press any letter on the selection switch panel, for example, A. Only the letter A should be showing in the message display. If “A MUG” is displayed, the sensor thinks there is a mug in the station. The fault could be one or more of the follow- ing:

Improper cup station alignment

Excessive sensitivity (the sensor is sensing the delivery door)

Cup station lens is not clean

Cleaning

As indicated in the Sanitation section, you should remove the cup station to clean it. Pay particular attention to the dark colored infrared mug/cup sensor lens, which is part of the cup station. If it is not thoroughly cleaned, the sensor will not work properly.

CAUTION

Do not get liquid inside the sensor unit.

Cleaning the infrared mug/cup sensor unit itself is not usually necessary. If it does require cleaning, just wipe it with a damp cloth.