Stardance Direct Vent/Natural Vent Gas Heater
Thermostat Connection (optional)
Use only a thermostat rated for 500 millivolts.
Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation.
Thermostat
Wire / Gauge
18
16
14
1.Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.
2.Connect the thermostat wires to the valve. (Fig. 51)
Install the Front Plate
Hold the front plate by the window bars and lift it into position, engaging the two steel tabs on the top corners behind the adjacent bosses in the side plates. (Fig. 52) Then seat the Front against the sides so the tabs at the bottom lip engage with the notches in the stove legs.
When properly installed, the bottom of the Front Plate cannot be pulled away from the sides without also lifting it.
Engage steel tabs gehind the cast iron bosses
Control Door
Bottom tabs engage |
|
notch in the leg. | ST474 |
Fig. 52 Install the front plate.
This completes assembly of the Stardance stove.
Operation
��������
��������������
������������
������������������
�������������
��������������������
���������������
The Stardance is operated with the front plate in place with the doors open or closed. To open the front doors, pull forward to separate the magnetic catch.
CAUTION: DO NOT TOUCH DOORS WHEN HOT!
Your First Fire
Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly, Figure 53. Follow the lighting instructions on Page 31 exactly.
During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air to alleviate the condition.
ST935
Fig. 53 Pilot assembly location.
Pilot and Burner Inspection
Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figure
55.If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for as- sistance. Do not operate the heater until the pilot flame is correct.
Follow regular maintenance procedures as described on Page 41.
20012734 | 29 |