Vermont Casting VCS5016 VCS3506BI / VCS5006BI Assembly, VCS3506BI / VCS5006BI FRAMING DIMENSIONS

Models: VCS4106 VCS3006 VCS5006 VCS5016 VCS3506 VCS5006BI VCS6006

1 36
Download 36 pages 8.83 Kb
Page 30
Image 30
VCS3506BI / VCS5006BI Assembly

VCS3506BI / VCS5006BI Assembly

 

 

 

 

 

 

 

 

 

 

 

 

VCS3506BI / VCS5006BI FRAMING DIMENSIONS

 

 

 

O

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

A

 

 

 

L

 

 

 

 

 

 

 

 

K

 

 

 

D

 

 

G

 

 

 

 

C

 

 

 

 

 

 

 

E

 

 

H

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

Fig. 2

 

 

 

 

 

 

 

 

 

I

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-Combustible Clearances

Combustible Clearances

 

 

With ZC Insulated Jacket

 

 

 

 

 

 

 

 

 

 

 

 

 

Ref.

 

VCS3506BI

 

VCS5006BI

VCS3506BI

VCS5006BI

A

 

23-3/4"[603.3mm]

 

23-3/4"[603.3mm]

23-3/4"[603.3mm]

23-3/4"[603.3mm]

B

 

4" [101.6mm]

 

4" [101.6mm]

3" [76.2mm]

3" [76.2mm]

C

 

2" [50.8mm] Dia.

 

2" [50.8mm] Dia.

2" [50.8mm] Dia.

2" [50.8mm] Dia.

D

 

2 1/8" [54.0mm]

 

2 1/8" [54.0mm]

2 1/8" [54.0mm]

2 1/8" [54.0mm]

E

 

3" [76.2mm]

 

3" [76.2mm]

3" [76.2mm]

3" [76.2mm]

F

 

2-1/2" [63.5mm] Min.

 

2-1/2" [63.5mm] Min.

2-1/2" [63.5mm] Min.

2-1/2" [63.5mm] Min.

G

 

2-1/2" [63.5mm] Min.

 

2-1/2" [63.5mm] Min.

2-1/2" [63.5mm] Min.

2-1/2" [63.5mm] Min.

H

 

9" [228.6mm]

 

9" [228.6mm]

10" [254.0mm]

10" [254.0mm]

I

 

31-3/8"[796.9mm]

 

43-3/8"[1101.7mm]

31-3/8"[796.9mm]

43-3/8"[1101.7mm]

J

 

12" [304.8mm]

 

12" [304.8mm]

12" [304.8mm]

12" [304.8mm]

K

 

18" [457.2mm]

 

18" [457.2mm]

18" [457.2mm]

18" [457.2mm]

L

 

10" [254.0mm]

 

10" [254.0mm]

10" [254.0mm]

10" [254.0mm]

M

 

18-3/4"[476.3mm]

 

18-3/4"[476.3mm]

18-3/4"[476.3mm]

18-3/4"[476.3mm]

N

 

4" [101.6mm] Min.

 

4" [101.6mm] Min.

4" [101.6mm] Min.

4" [101.6mm] Min.

O

 

4" [101.6mm] Min.

 

4" [101.6mm] Min.

4" [101.6mm] Min.

4" [101.6mm] Min.

Note: Ensure that your grill enclosure has been constructed according to the exact specifications shown in Fig.

2.If the enclosure is constructed of wood or other similar combustible materials, the use of the insulated jacket Model VCIJ35A or VCIJ50A is required.

If you have an L.P. model with a 20lb cylinder stored in the enclosure, ensure that there at least two air ventilation openings of 10sq inches 180 degrees apart and they are level with the cylinder valve. Another two openings with the same dimensions and distance are required to be level with the base of the cylinder. For other requirements, see section 1.7 of ANSI Z21.58-2005/CGA 1.62005 American National Standard/ Canadian Gas Association Standard for outdoor cooking gas appliances.