FOR ALTERNATIVE PIPING METHODS TO CON-

 

 

 

Installation Manual

 

 

 

 

ENGLISH

FOR ALTERNATIVE PIPING METHODS TO CON-

 

 

 

NECT THE APPLIANCE TO THE GAS SUPPLY, A

 

 

 

TRAINED SERVICE MAN OR GAS APPLIANCE IN-

 

 

 

STALLER MUST MAKE THE GAS SUPPLY�CON-

 

 

 

NECTION. Leak testing of the appliance shall be

 

MANIFOLD

conducted by the Installer according to the In-

 

ENTRANCE

 

 

 

structions given.

 

 

FLARE

Unless prohibited by local codes or ordinances, a new

 

 

UNION

GASKET

GASKET

ADAPTOR

A.G.A. - Certified, flexible metal appliance connector

 

may be used to connect this appliance to its gas sup-

FLARE UNION

1/2" NPT

ply. The connector must have an internal diameter not

ADAPTOR

APPLIANCE

PIPE NIPPLE

less than nominal 1/2” NPT pipe and be no more than

ELBOW

PRESSURE

 

 

5 feet in length. A 1/2” NPT x 1/2” flare union adapter

REGULATOR,

 

FLEXIBLE

is required at each end of the flexible connector.

SUPPLIED (OBSERVE

APPLIANCE

DIRECTIONALITY

CONNECTOR

If a flexible connector is used assure that both the ap-

OF GAS FLOW)

 

(5 FT.) MAX

pliance pressure regulator and manual shut-off valve

FLARE

(1.52 m) MAX

are joined solidly to other permanent hard piping (ei-

UNION

 

FLARE

ther gas supply or the appliance manifold) so as to be

ADAPTOR

 

UNION

 

 

physically stationary. See figure 12.

FLEXIBLE

 

ADAPTOR

APPLIANCE

 

 

APPLIANCE

 

 

PRESSURE REGULATOR,

CAUTION

CONNECTOR

SUPPLIED (OBSERVE

(5 FT.) MAX

Do not attempt to attach the flexible connector directly

(1.52 m) MAX

DIRECTIONALITY

OF GAS FLOW)

to an external pipe thread.

 

 

 

Connection requires flare union adapters.

FLARE

 

1/2" NPT

 

 

UNION

PIPE NIPPLE

For Massachusetts Installations:

ADAPTOR

 

 

GAS

 

GAS

1. Shut-off valve must be a "T" handle gas cock.

 

SHUT-OFF

 

SHUT-OFF

2. Flexible gas connector must not be longer than 36

VALVE

 

VALVE

3.

inch.

1/2" NPT PIPE

1/2" NPT PIPE

Not approved for installation in a bedroom or a

(STATIONARY

(STATIONARY

 

bathroom unless unit is direct vent.

SUPPLY PIPE)

SUPPLY PIPE)

 

 

 

 

 

 

NO APPLIANCE

WALL OVEN MOUNTED

 

 

MOUNTED BELOW

IN CABINETRY BELOW

 

 