Converting Appliances for Use with NG Gas

Installation Manual

ENGLISH

After injectors replacement adjust the burner flame (see Low Flame Adjustment paragraph).

Check the appearance of each burner’s flame at HI- LO settings, if the flame appear too large or too small make sure that all steps were completed correctly.

Convert the pressure regulator on LP position fol- lowing the illustration 20.

Converting Appliances for Use with NG Gas

If this appliance should be converted for use with gas NG (natural gas), each of the following modifications must be performed.

1.Replace all injectors following the step described on page 18, observe the number stamped on the side, this number codes the orifice diameter and its correct burner location (following the illustration of injectors position).

2.Convert the pressure regulator on LP position (fol- lowing the illustration of pressure regulator con- version).

3.Adjust the burner flame (see Low Flame Adjust- ment paragraph).

Check the appearance of each burner’s flame at HI- LO settings, if the flame appears too large or too small make sure that all steps were completed correctly.

Pressure regulator conversion

The appliances is designed for use with NG gas or LP gas. The gas pressure regulator is supplied. It must be installed in the gas way ahead of manifold en- trance. It is pre-set for use with the gas supplied with the appliances. For use with different gas must be converted.

For the pressure regulator conversion following the below instructions:

￿￿Disconnect all electrical power, at the main circuit breaker or fuse box.

￿￿Shut off the gas supply to the cooktop by closing the manual shut-off valve.

￿￿Adjust the pressure regulator, by following the in- struction (see figure)

1.Unscrew the regulator cap

2.Unscrew the plastic conversion plug from the cap turn over and screw back (wide section away from cap for LP and against cap for NG) see figures below.

3.Replace the cap regulator.

Before replace the regulator cap.

Check the position of plug.

Suitable for the gas converted.

Figure 20. Pressure regulator conversion