Use & Care Manual

ENGLISH

The control uses only the 15% of the available power, divided in 0 to 9 steps with a better accuracy.

Keep in mind that power level 9 in this special mode correspond exactly to level 4 in the standard range.

Select the zone and touch the [LOW TEMP] key again in order to disable the Low Power Scale and restore the standard one, without switching off the zone.

Pay attention: the level remains the same but the power increases.

Switching off a cooking zone as described below disables the Low Power mode. When the zone will be selected again it will start to work in the standard power mode.

Switching an element off

Touch the related [OFF] key (ref.1) in order to stop a heating element.

You may turn off all active elements at the same time by touching the main [ON/OFF] key.

Dual element activation (36” only)

Select a double heating area touching the related [ON] key, the HOT SURFACE led (ref.3) begins to flash.

The external element is automatically actuated only if the diameter of the pan is a little bit larger than the inner circle.

The dual element enabling indication (ref.5a) is on when the element is enabled, is off when the element is disabled.

Hot surface indicator light

Each element has a HOT SURFACE indicator light (ref.3) to show when the cooking area is hot.

This indication turns on when the zone is activated and remains ON until the cooking area has cooled down to a “safe to touch” temperature (approximately 150°F).

If a hot surface light is ON use caution when working around the cooktop as it is still hot.

Fast Boil (Booster) function

Once a heating element has been selected, touch the [FAST BOIL] key to enable/disable this function, before or after setting the power level.

A beep sounds and the heater display shows the selected power level and a “P” alternatively. The “Peacock Tail” shows the selected power level.

The heater works using some extra power available

only for some minutes then it gets back to the selected power level.

This option is available for all the cooking zones, both standard, both special ones (multiple zones).

Key Lock function

The key lock function is activated or deactivated holding the [LOCK] key for 2 seconds. The lock indication turns on, the keyboard is locked. Of course, the [LOCK] key itself is always enabled.

The keys are automatically locked at start-up.

The locking function can be activated regardless of the heaters condition (working or not). The key lock function locks all the keys but the [OFF] ones. Also the general [ON/OFF] key remains active for the off function.

Setting the timer

It works as a minute minder and it doesn’t stop any heating element.

The timer is available in some models only. It can be set independently from the heating element, even if there aren’t any working zones. If the cooktop is not working, touch first the main [ON/OFF] key to enter stand-by mode, with all displays showing “0”.

2

1

3

Figure. 9

Touch [T-] or [T+] keys to set the timer: the initial value starts from “00” or “45” respectively on the timer display (ref.1). Hold the key in order to fasten the increase/ decrease speed. The maximum value is “99”.

The timer led (ref.2) indicates whether the timer is running.

The dot in the lower right corner of the display (ref.3) is flashing when the timer has been selected in order to change its value. After 5 seconds since the last touch the new value is accepted and the dot disappears.

11

Page 11
Image 11