6Serial Communications

To interface the DView with a home theater automation/control system or a PC running terminal emulation software, connect it to your control system or PC as shown in Figure 3-9.(Use a straight-through cable.)

Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit and no flow control. Set the baud rate to match that of the DView RS-232 port. To check the baud rate setting, select Baud Rate from the ISF Calibration menu (refer to page 40).

6.1

RS-232 Connection and Port Configuration

Commands are in ASCII format and are not case-sensitive.

A carriage return is not required after a command.

When you send a valid command, the DView executes it and acknowledges it with a right-bracket character (]) followed by the four-digit numeric code you sent; for example,

]0002.

When you send an invalid command (one followed by values outside the valid range for that command), the DView ignores it and returns >MAX or <MIN instead of the four-digit code.

When you send an unrecognized/misspelled command, the DView ignores it and returns -N/Ainstead of the four-digit code.

Table 6-1lists the RS-232 command set.

Table 6-1. Serial Commands

 

Command

 

 

Description

 

 

 

 

 

 

[

 

S3A

 

0###

Set audio volume to ### ( = 000-100)

 

 

 

 

Example: [S3A0075 sets volume to 75

 

 

 

 

 

 

[

 

+3A

 

 

Audio volume up

 

 

 

 

 

 

[

 

-3A

 

 

Audio volume down

 

 

 

 

 

 

[

 

S3E

 

000#

Audio mute (speakers/headphones)

 

 

 

 

 

0

= not muted, 1 = muted

 

 

 

 

Example: [S3E0001 mutes the audio output

 

 

 

 

 

 

[

 

S4A

 

000#

Main input selection

 

 

 

 

 

1

= Input1

 

 

 

 

 

2

= Input2

 

 

 

 

 

3

= Input3

 

 

 

 

 

4

= Input4

 

 

 

 

 

6

= RGB

 

 

 

 

 

8

= HDMI1

 

 

 

 

 

9

= HDMI2

 

 

 

 

Example: [S4A0006 selects RGB

 

 

 

 

 

 

[

 

+4A

 

 

Select “next” Main AV input

 

 

 

 

 

 

 

6.2

Serial Command Syntax

Vidikron VL-52 and VL-57 Installation/Operation Manual