Indicator Message
The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.
|
|
| Table 10: Indicator Message | |
POWER | LAMP | TEMP | Contents | |
indicator | indicator | indicator | ||
| ||||
|
|
|
| |
Lit | Turns off | Turns off | The Standby mode has been set. | |
orange | ||||
|
|
| ||
|
|
|
| |
Blinks | Turns off | Turns off | Warming up. Please wait. | |
green | ||||
|
|
| ||
|
|
|
| |
Lit | Turns off | Turns off | ON. Normal operation possible. | |
green | ||||
|
|
| ||
|
|
|
| |
Blinks | Turns off | Turns off | Cooling down. Please wait. | |
orange | ||||
|
|
| ||
|
|
|
| |
|
|
| Lamp is not lit. | |
|
|
| The interior of the equipment may be too hot. Switch power | |
|
|
| OFF, wait 20 minutes until the equipment cools, and check | |
Lit red | Lit red | Turns off | whether the ventilation openings are blocked, whether the air | |
|
|
| filter is dirty, or whether the ambient temperature exceeds 35 | |
|
|
| °C. And switch power ON again. Replace the lamp if the same | |
|
|
| problem occurs. | |
|
|
|
| |
|
|
| Lamp or lamp cover is not found, or hasn’t been fitted in | |
|
|
| correctly. | |
Lit red | Blinks | Turns off | Switch power OFF, and wait for 45 minutes until the equipment | |
red | cools. Check fitting of the lamp and lamp cover, and switch | |||
|
| |||
|
|
| power ON again. Contact your dealer if the same problem | |
|
|
| occurs again. | |
|
|
|
| |
|
|
| The cooling fan is not operating. | |
|
| Blinks | Switch power OFF, and wait for 20 minutes until the equipment | |
Lit red | Turns off | cools. Check for foreign matters in the fan, and switch power | ||
red | ||||
|
| ON again. Contact your dealer if the same problem occurs | ||
|
|
| ||
|
|
| again. | |
|
|
|
| |
|
|
| The interior of the equipment is too hot. | |
|
|
| Switch power OFF, and wait for 20 minutes until the equipment | |
|
|
| cools. Check whether the ventilation openings | |
Lit red | Turns off | Lit red | are blocked, whether the air filter is dirty, or whether the ambient | |
|
|
| temperature exceeds 35 °C. Then switch power | |
|
|
| ON again. Contact your dealer if the same problem occurs | |
|
|
| again. | |
|
|
|
|
NOTE: • When the internal temperature becomes excessive, power is switched OFF automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and wait for 20 minutes until the equipment has cooled sufficiently.
ViewSonic PJ1065 | 21 |