Indicator Message

Indicator Message

The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the appropriate measures.

 

 

 

Table 10: Indicator Message

POWER

LAMP

TEMP

Contents

indicator

indicator

indicator

 

 

 

 

 

Lit

Turns off

Turns off

The Standby mode has been set.

orange

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Warming up. Please wait.

green

 

 

 

 

 

 

 

Lit

Turns off

Turns off

ON. Normal operation possible.

green

 

 

 

 

 

 

 

Blinks

Turns off

Turns off

Cooling down. Please wait.

orange

 

 

 

 

 

 

 

 

 

 

Lamp is not lit.

 

 

 

The interior of the equipment may be too hot. Switch power

 

 

 

OFF, wait 20 minutes until the equipment cools, and check

Lit red

Lit red

Turns off

whether the ventilation openings are blocked, whether the air

 

 

 

filter is dirty, or whether the ambient temperature exceeds 35

 

 

 

°C. And switch power ON again. Replace the lamp if the same

 

 

 

problem occurs.

 

 

 

 

 

 

 

Lamp or lamp cover is not found, or hasn’t been fitted in

 

 

 

correctly.

Lit red

Blinks

Turns off

Switch power OFF, and wait for 45 minutes until the equipment

red

cools. Check fitting of the lamp and lamp cover, and switch

 

 

 

 

 

power ON again. Contact your dealer if the same problem

 

 

 

occurs again.

 

 

 

 

 

 

 

The cooling fan is not operating.

 

 

Blinks

Switch power OFF, and wait for 20 minutes until the equipment

Lit red

Turns off

cools. Check for foreign matters in the fan, and switch power

red

 

 

ON again. Contact your dealer if the same problem occurs

 

 

 

 

 

 

again.

 

 

 

 

 

 

 

The interior of the equipment is too hot.

 

 

 

Switch power OFF, and wait for 20 minutes until the equipment

 

 

 

cools. Check whether the ventilation openings

Lit red

Turns off

Lit red

are blocked, whether the air filter is dirty, or whether the ambient

 

 

 

temperature exceeds 35 °C. Then switch power

 

 

 

ON again. Contact your dealer if the same problem occurs

 

 

 

again.

 

 

 

 

NOTE: • When the internal temperature becomes excessive, power is switched OFF automatically for safety reasons, and the indicator is extinguished. Set the power switch to [O] and wait for 20 minutes until the equipment has cooled sufficiently.