ViewSonic PJ1173 Command Control via the Network, Communication Port, Command Control Settings

Models: PJ1173 VS12109

1 127
Download 127 pages 1.43 Kb
Page 103
Image 103
Command Control via the Network

Management with Web browser software

Command Control via the Network

You can configure and control the projector via the network using RS-232C commands.

Communication Port

The following two ports are assigned for the command control. TCP #23

TCP #9715

NOTE • Command control is not available via communication port (TCP #9716) that is used for the e-SHOT transmission function.

Command Control Settings

Configure the following items from a web browser when command control is used. Example: If the IP address of the projector is set to 192.168.1.10:

1)Enter “http://192.168.1.10/” into the address bar of the web browser.

2)Enter the Administrator ID and password and click [Logon].

3)Click [Port Settings] on the main menu.

4)Click [Enable] check box to open Network Control Port1 (Port: 23) to use TCP #23. Click [Enable] check box for [Authentication] setting when authentication is required, otherwise clear the check box.

5)Click [Enable] check box to open Network Control Port2 (Port: 9715) to use TCP #9715. Click [Enable] check box for [Authentication] setting when authentication is required, otherwise clear the check box.

6)Click [Apply] button to save the settings.