Management with Web browser software

Command Control via the Network

You can configure and control the projector via the network using RS-232C commands.

Communication Port

The following two ports are assigned for the command control. TCP #23

TCP #9715

NOTE • Command control is not available via communication port (TCP #9716) that is used for the e-SHOT transmission function.

Command Control Settings

Configure the following items from a web browser when command control is used. Example: If the IP address of the projector is set to 192.168.1.10:

1)Enter “http://192.168.1.10/” into the address bar of the web browser.

2)Enter the Administrator ID and password and click [Logon].

3)Click [Port Settings] on the main menu.

4)Click [Enable] check box to open Network Control Port1 (Port: 23) to use TCP #23. Click [Enable] check box for [Authentication] setting when authentication is required, otherwise clear the check box.

5)Click [Enable] check box to open Network Control Port2 (Port: 9715) to use TCP #9715. Click [Enable] check box for [Authentication] setting when authentication is required, otherwise clear the check box.

6)Click [Apply] button to save the settings.

ViewSonic

98

PJ1173

Page 103
Image 103
ViewSonic PJ1173, VS12109 warranty Command Control via the Network, Communication Port, Command Control Settings