VISTA-10SE Installation and Setup Guide

5-6

5800 Series Transmitters Table (continued)

Model Description Input Type and Special Notes

5817
(cont'd.)
Multi-Point Universal
Transmitter (cont'd.) DIP Switches: Set all DIP switches to the OFF position when enrolling the
serial number.
NOTE: All loops must be assigned the same input type.
5818 Recessed Magnetic
Contact Transmitter Enroll as 3 for RF (supervised).
5819
5819BRS
5819WHS
Shock Processor
Transmitter Enroll as 3 for RF (supervised).
Has three unique input (loop) zones: one for a wired closed-circuit contact loop,
one for use with inertia-type shock detectors (mounted externally), and one for a
built-in reed switch (used in conjunction with a magnet).
5849
5850
5852
Glassbreak
Detector/Transmitter Enroll as 3 for RF (supervised).
5890
5890P1 PIR Detector/
Transmitter Enroll as 3 for RF (supervised).
The cover must be on the unit when enrolling the serial number.

When enrolling a transmitters ID code(s), any PIR in the vicinity that is not being enrolled

should be covered with a cloth, tissue, etc. to prevent activation.

Installing 5800 Series Transmitters

To be sure reception of the transmitter's signal at the proposed mounting location is

adequate, perform a Go/No Go Test in the TESTING the SYSTEM section.

Setting DIP Switches on the 5827 Transmitter(s)

You must set a 5827 Transmitter to the programmed House ID, using its DIP switches.

DIP SWITCH POSITION
12345
1 ----UP
2 ---UP-
3 - - - UP UP
4--UP--
5--UP-UP
6--UPUP-
7 - - UPUPUP
8 -UP---
9 - UP - - UP
10 - UP - UP -
11 - UP - UP UP
12 - UP UP - -
13 - UP UP - UP
14 - UPUPUP -
15 - UPUPUPUP
16UP----
DIP SWITCH POSITIONHOUSE
ID 12345
17 UP - - - UP
18 UP - - UP -
19 UP - - UP UP
20 UP - UP - -
21 UP - UP - UP
22 UP - UP UP -
23 UP - UPUPUP
24 UP UP - - -
25 UP UP - - UP
26 UP UP - UP -
27 UP UP - UP UP
28 UP UP UP - -
29 UP UP UP - UP
30 UP UP UP UP -
31 UP UP UP UP UP
SWITCH UP FOR "ON"
SWITCH DOWN FOR "OFF"
SHOWN SET FOR
HOUSE ID # 30