Section 1 - Introduction
1-3
Alarm Output
• Provides a 12VDC, 2 AMP output that can drive the compatible sounders listed in the
EXTERNAL SOUNDERS section (assumes a fully charged battery is connected).
• Steady output for burglary/panic, or temporal pulse sound ing output for fire notification,
as required by UL.
• Uses current-limiting circuitry for protection.
Auxiliary Power Output
• Provides 12VDC, 500mA maximum. Uses current limiting circuitry for protection.
• This output interrupts for smoke detector reset if 4-wire smoke detectors are used.
Programming
• Programmed options are stored in electrically erasable, nonvolatile EEPROM memory
(information can be reprogrammed at any time and will not be lost in the event o f a power
loss).
• The system can be uploaded, downloaded, or controlled via an IBM-compatible comp uter,
using ADEMCO's Compass Windows downloading software, and a modem specified by
ADEMCO.
Keypad programming consists of:
• Data field programming.
• Interactive (menu) mode programming.
For programming from a keypad, a 6139 2-line alpha keypad must be connected (but need not
stay in the system).
Communication Formats Supported
��� ADEMCO Low Speed (Standard or Expanded)
• Sescoa/Radionics (Standard or Expanded)
• ADEMCO Express
• ADEMCO Contact ID
Zone Descriptors
You can assign alpha descriptors to all zones (useful only w hen using alpha keypads and/or
the 4285/4286 VIP Module).
AC Power Supply
Uses No. 1321, 120VAC plug-in transformer with 16.5VAC 25VA output (1321CN in
Canada).
Backup Battery
Rechargeable (Sealed Lead Acid) 12VDC, 4AH minimum.