171

SECTION 17

Zone Lists

(81 Menu Mode)

••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
About Zone List Menu Mode Zone List Display s
••••••••••••••••••••••••••••••••••••••••••••••••••

About Zone List Menu Mode

Zone List Menu mode is used to program zone lists for output devices (programmed in 80
Menu mode). Refer to the Programming Form worksheet (81) that programs the Zone Lists
for Output Devices.
To program the zone lists, press 81 while in Program mode.

Zone List Displays

Zone List No.
(00 = Quit) 01
Enter the Zone List Number 01, 02, or 03 you want to program (or
00 to end these entries). Press [] to advance.
In the following displays, zone list 01 has been selected for
programming.
01 Enter Zn Num.
(00 = Quit) 00
Enter each zone number to add to the zone list by first entering th e
zone number, then (for example, 01, 02, 03). After all zones
desired are entered, press 00 to advance.
IMPORTANT: Do not include fire zones in zone lists that are used
to STOP relay actions.
01 Del Zn List?
0 = No 1 = Yes 0
To delete the zone list, enter 1 (Yes). All zones in the zone list are
deleted automatically, and programming returns to the f irst
screen.
To save the zone list, enter 0 (No) to advance.
01 Delete Zone?
0 = No 1 = Yes 0
To save the entire zone list, enter 0 (No). Programming returns to
the first screen.
To delete a zone or zones in a zone list, enter 1 (Yes) to advance.
01 Zn to Delete?
(00 = Quit) 00
Enter each zone to be deleted from the list, followed by . After all
zones to be deleted are entered, enter 00 to return to the first
screen so that another list can be programmed, if desired.
Any list may include any or all of the system's zone numbers except zone 08.
A zone list can be assigned to more than one output relay.