trigger

boot,

boot

6/6

Indicate the trigger condition:

 

di,

 

 

“boot” = System boot

 

motion,

 

 

“di”= Digital input

 

seq,

 

 

“motion” = Video motion detection

 

recnotify,

 

 

“seq” = Periodic condition

 

tampering,

 

 

“visignal” = Video input signal loss.

 

visignal,

 

 

“recnotify” = Recording notification.

 

vi

 

 

“tampering” = Tamper detection.

 

 

 

 

“vi”= Virtual input (Manual trigger)

 

 

 

 

“volalarm” = Audio detection.

 

 

 

 

 

triggerstatus

String[40]

trigger

6/6

The status for event trigger

 

 

 

 

 

di

<integer>

1

6/6

Indicate the source id of di trigger.

 

 

 

 

This field is required when trigger

 

 

 

 

condition is “di”.

 

 

 

 

One bit represents one digital input.

 

 

 

 

The LSB indicates DI 0.

 

 

 

 

 

mdwin

<integer>

0

6/6

Indicate the source window id of

 

 

 

 

motion detection.

 

 

 

 

This field is required when trigger

 

 

 

 

condition is “md”.

 

 

 

 

One bit represents one window.

 

 

 

 

The LSB indicates the 1st window.

 

 

 

 

For example, to detect the 1st and 3rd

 

 

 

 

windows, set mdwin as 5.

 

 

 

 

 

mdwin0

<integer>

0

6/6

Similar to mdwin. The parameter

 

 

 

 

takes effect when profile 1 of motion

 

 

 

 

detection is enabled.

 

 

 

 

 

vi

<integer>

0

6/6

Indicate the source id of vi trigger.

 

 

 

 

This field is required when trigger

 

 

 

 

condition is “vi”.

 

 

 

 

One bit represents one digital input.

 

 

 

 

The LSB indicates VI 0.

 

 

 

 

 

inter

1~999

1

6/6

Interval of snapshots in minutes.

 

 

 

 

This field is used when trigger

 

 

 

 

condition is “seq”.

 

 

 

 

 