VIVOTEK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_top

0 ~ 240

0

4/4

Top coordinate of

 

 

 

 

 

 

window position.

 

 

 

 

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_width

0 ~ 320

0

4/4

Width of motion

 

 

 

 

 

 

detection window.

 

 

 

 

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_height

0 ~ 240

0

4/4

Height of motion

 

 

 

 

 

 

detection window.

 

 

 

 

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_objsize

0 ~ 100

0

4/4

Percent of motion

 

 

 

 

 

 

detection window.

 

 

 

 

 

 

 

 

 

i<0~(m-1)>_win_i<0~2>_sensitivity

0 ~ 100

0

4/4

Sensitivity of

 

 

 

 

 

 

motion detection

 

 

 

 

 

 

window.

 

 

 

 

 

 

 

 

7.16 Tempering detection settings

Group: tampering_c<0~(n-1)>for n channel product (capability.tampering > 0)

 

NAME

 

 

VALUE

 

 

DEFAULT

 

 

SECURITY

 

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

(get/set)

 

 

 

 

 

enable

 

 

<boolean>

 

0

 

4/4

 

 

Enable or disable tamper detection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

threshold

 

0 ~ 255

 

120

 

1/7

 

 

Threshold of tamper detection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

duration

 

10 ~ 20

 

2

 

1/7

 

 

If tampering value exceeds the ‘threshold’ for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

more than ‘duration’ second(s), then tamper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

detection is triggered.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User's Manual - 171

Page 171
Image 171