VIVOTEK

triggerstatus

String[40]

trigger

6/6

The status for event trigger

 

 

 

 

 

exttriggerstatus

trigger,

<blank>

6/6

The status for event DI 1 trigger

 

normal~trigger

 

 

 

 

,

 

 

 

 

trigger~norma

 

 

 

 

l

 

 

 

 

 

 

 

 

exttriggerstatus1

trigger,

<blank>

6/6

The status for event audio detection

 

normal~trigger

 

 

profiletrigger

 

,

 

 

 

 

trigger~norma

 

 

 

 

l

 

 

 

 

 

 

 

 

di

<integer>

1

6/6

Indicate the source id of di trigger.

 

 

 

 

This field is required when trigger

 

 

 

 

condition is “di”.

 

 

 

 

One bit represents one digital input. The

 

 

 

 

LSB indicates DI 0.

 

 

 

 

 

mdwin

<integer>

0

6/6

Indicate the source window id of motion

 

 

 

 

detection.

 

 

 

 

This field is required when trigger

 

 

 

 

condition is “md”.

 

 

 

 

One bit represents one window.

 

 

 

 

The LSB indicates the 1st window.

 

 

 

 

For example, to detect the 1st and 3rd

 

 

 

 

windows, set mdwin as 5.

 

 

 

 

 

mdwin0

<integer>

0

6/6

Similar to mdwin. The parameter takes

 

 

 

 

effect when profile 1 of motion detection

 

 

 

 

is enabled.

 

 

 

 

 

vi

<integer>

0

6/6

Indicate the source id of vi trigger.

 

 

 

 

This field is required when trigger

 

 

 

 

condition is “vi”.

 

 

 

 

One bit represents one digital input. The

 

 

 

 

LSB indicates VI 0.

 

 

 

 

 

valevel

0,1

0

6/6

Select audio detection event.

 

 

 

 

0: not select

 

 

 

 

1: select

 

 

 

 

 

valevel0

0,1

0

6/6

Select audio detection profile event.

 

 

 

 

0: not select

 

 

 

 

1: select

 

 

 

 

 

User's Manual - 191

Page 191
Image 191