VIVOTEK

Command: queryStatus

PARAMETER

 

VALUE

 

DESCRIPTION

 

retType

 

xml or javascript

 

Optional.

 

 

 

 

 

Ex. retype=javascript

 

 

 

 

 

The default return message is in XML format.

 

 

 

 

 

 

 

Ex. Query local storage status and call for javascript format return message.

http://<servername>/cgi-bin/admin/lsctrl.cgi?cmd=queryStatus&retType=javascript

Virtual input (capability.nvi > 0)

Note: Change virtual input (manual trigger) status.

Method: GET

Syntax:

http://<servername>/cgi-bin/admin/setvi.cgi?vi0=<value>[&vi1=<value>][&vi2=<value>] [&return=<return page>]

 

PARAMETER

 

 

 

VALUE

 

 

DESCRIPTION

 

 

vi<num>

 

 

 

state[(duration)nstate]

 

 

Ex: vi0=1

 

 

 

 

 

 

 

 

 

 

Setting virtual input 0 to trigger state

 

 

 

 

 

 

 

Where "state" is 0, 1. “0”

 

 

 

 

 

 

 

 

 

 

means inactive or normal

 

 

 

 

 

 

 

 

 

 

 

 

Ex: vi0=0(200)1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

state while “1” means

 

 

Setting virtual input 0 to normal state, waiting 200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

active or triggered state.

 

 

milliseconds, setting it to trigger state.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Where "nstate" is next

 

 

Note that when the virtual input is waiting for next state, it

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

state after duration.

 

 

cannot accept new requests.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

return

 

 

 

<return page>

 

 

Redirect to the page <return page>after the request is

 

 

 

 

 

 

 

 

 

 

completely assigned. The <return page>can be a full URL

 

 

 

 

 

 

 

 

 

 

path or relative path according the current path. If you omit

 

 

 

 

 

 

 

 

 

 

this parameter, it will redirect to an empty page.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return Code

 

 

 

Description

 

 

 

 

 

200

 

 

 

The request is successfully executed.

 

400The request cannot be assigned, ex. incorrect parameters. Examples: setvi.cgi?vi0=0(10000)1(15000)0(20000)1

No multiple duration. setvi.cgi?vi3=0

User's Manual - 217