All necessary accessories can be found in the product package except for the Ethernet cable that depends on the user’s environment. The Ethernet cable should meet UTP category 5 that cannot exceed 100 meters.

Connect the jack of the power adapter to Network Camera prior to plugging the utility end into the utility power socket. It will reduce accidental electric surge shock.

As soon as the power adapter is plugged into the utility socket, the front LED will switch between green and red for several times. After passing the self-test, the LED will shut off and Network Camera will standby for software installation. Otherwise refer to Appendix A for troubleshooting.

Network Camera provides a general I/O terminal block with one digital input and one relay switch for device control. Pin 1 and pin 2 can be connected to an external sensor and the state of voltage will be monitored from the initial state 'LOW'. The relay switch of

pin 3 and pin 4 can be used to turn on or off the external device.

Consult with the dealer of the peripherals for correct installation.1

1

DI+

INPUT (Max. 50mA, 12VDC)

2

DI-

INPUT (Initial state of DI is low)

3SW_COMMON OUTPUT (open from SW_OPEN at initial state) (close with SW_OPEN when set DO to ON)

4 SW_NOPEN

OUTPUT (Max. 1A, 24VDC or 0.5A, 125VAC)