Thermostat User Guide

Installer Settings Summary

Setting

Range

Default

 

 

 

 

 

Display Lock

Y or N

N

Locks out front buttons

 

 

 

 

F/C Mode

C or F

F

 

 

 

 

 

Screen Timeout

0-240

0

seconds

 

 

 

 

 

 

 

 

Schedule Enable

Y or N

N

 

 

 

 

 

 

 

 

 

Max heat setpoint

55F-90F (12C-32C)

90F (32C)

 

 

 

 

 

Min cool setpoint

60F-99F(15C-37C)

55F (15C)

 

 

 

 

 

 

Min Run Time (MRT)

1

– 9

3

 

 

 

 

 

 

Min Off Time (MOT)

5

– 9

5

 

 

 

 

 

Mechanical - Type

Std or HP

Std

 

 

 

 

 

Mechanical - Fan Type

Gas or Elec

Gas

 

 

 

 

 

Mechanical - C/O Type

w/Heat or w/Cool

w/Cool

 

 

 

 

 

Mechanical - 2nd Stage

Y or N

N

 

Heat

 

 

 

 

 

 

 

 

Mechanical - Aux Heat

Y or N

Y

 

 

 

 

 

Mechanical - 2nd Stage

Y or N

N

 

Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Filter Interval

 

 

300

 

 

 

 

 

 

Maint Interval

 

 

3000

 

 

 

 

 

 

 

 

 

 

 

H/C Delta

3

– 15

3

 

 

 

 

 

 

Heat Delta Stage 1 On

1

– 8

1

 

 

 

 

 

 

Heat Delta Stage 1 Off

0

– 8

0

 

 

 

 

 

 

Heat Delta Stage 2 On

1

– 8

2

 

 

 

 

 

 

Heat Delta Stage 2 Off

0

– 8

0

 

 

 

 

 

 

Heat Delta Stage 3 On

1

– 8

3

 

 

 

 

 

 

Heat Delta Stage 3 Off

0

– 8

0

 

 

 

 

 

 

Cool Delta Stage 1 On

1

– 8

1

 

 

 

 

 

 

Cool Delta Stage 1 Off

0

– 8

0

 

 

 

 

 

 

Cool Delta Stage 2 On

1

– 8

2

 

 

 

 

 

 

Cool Delta Stage 2 Off

0

– 8

0

 

 

 

 

 

 

Fan Cycler ON time

0

– 120

0

0 = Fan Cycler OFF

 

 

 

 

Fan Cycler Off Time

10 – 120

10

 

 

 

 

 

 