Vulcan-Hart 1GR85M ML-136410 manual Gas Pressures All Models, Testing The Gas Supply Piping System

Models: 1GR35M ML-136407 1GR65M ML-136409 1GR45MF ML-136785 1GR45M ML-136408 1GR65MF ML-136786 1GR85M ML-136410 1GR85MF ML-136787 2GR45MF ML-136417 2GR65MF ML-136418 2GR85MF ML-136419 3GR65MF ML-136421 3GR45MF ML-136420 3GR85MF ML-136422 4GR45MF ML-136423

1 24
Download 24 pages 43.9 Kb
Page 8
Image 8
GAS PRESSURES (ALL MODELS):

GRM SERIES GAS FRYERS

Prior to lighting, check all joints in the gas supply line for leaks.

Use soap and water solution. Do not use an open flame.

After piping has been checked for leaks, fully purge gas pipes to remove air.

GAS PRESSURES (ALL MODELS):

The gas pressure should be set at 4” W.C. (Water Column) (0.8 kPa) for natural gas and 10” W.C. (2.75 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an additional pressure regulator must be installed.

TESTING THE GAS SUPPLY PIPING SYSTEM:

When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve must be disconnected from the gas supply piping system.

When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas supply piping system by closing its individual shutoff valve.

Fryers with Casters:

Separate instructions for installing casters are included with the casters:

The installation shall be made with a connector that complies with the

Standard for Connectors for Movable Gas Appliances, ANSI Z21.69, CAN/CGA- 6.16, and a quick-disconnect device that complies with the Standard for Quick- Disconnect Devices for Use with Gas Fuel, ANSI z21.41 CSA 6.9 or Quick- Disconnect Devices for Use with Gas Fuel,

When installing a quick disconnect you must also install a means for

limiting the movement of the fryer. This device will prevent the gas line or quick disconnect from being strained. The restraining device should be attached to the cutout on the back panel. See illustration for location.

VULCAN-HART

F-31233 Rev. K (February 2011)