DIRECT IGNITION LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance
•Do not touch any electrical switch
•Do not use any phone in your building.
•Immediately call your gas supplier from a neighbor's phone.
•Follow the gas supplier's instructions.
•If you can not reach your gas supplier, call the fire department.
B.Use only the wall switch or remote control switch to turn the gas control on/off.Any attempted repairs or adjustments should be performed by a qualified service technician.Applying force or attempted repair may result in a fire or explosion.
C.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1.STOP! Read the safety information above.
2.Turn off all electric power to the appliance.
3.This appliance is equipped with an ignition device that automatically lights the burner. Do not try to light the burner by hand.
4.Open bottom louver assembly, or open valve access door.
5.Turn gas line valve to "ON."
6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "A" in the safety information on reverse. If you do not smell gas, go to the next step.
7.Close bottom louver assembly, or close hearth access plate.
8.Turn on all electric power to the appliance.
9.If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE," and call your service technician or gas supplier.
ON
OFF
TO TURN OFF GAS TO APPLIANCE
1. STOP! Read the safety information above. | 5. Close bottom louver assembly, or close valve access door. |
2.Turn off all electric power to the appliance.
3.Open bottom louver assembly, or open the valve access door.
4.Turn gas line valve to "OFF."
INITIAL START UP GAS LINE PURGE
NOTE: UNIT MUST BE PROPERLY GROUNDED FOR ELECTRONIC IGNITION TO FUNCTION.
On initial installation, or after extended periods where the fireplace has not been used, gas lines may require purging.