JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS
STANDARD MILLIVOLT VALVE MODELS
CAUTION: ALLWIRING SHOULD BE DONE BYA QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLYIS DISCONNECTED.THEAPPLIANCE,WHEN INSTALLED, MUSTBE ELECTRICALLYGROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).
A factory installed junction box is located on the lower right side of the fireplace. Wiring must be fed to the junction box and attached to the receptacle that is provided. Leave approximately 6" of wire in the junction box for connection.
Attach black wire to one side of the receptacle and white wire to opposite side of receptacle. The ground wire should be attached to the green (ground) screw.
Install the receptacle into the junction box. Attach cover |
|
plate. | Figure 28 |
120V DIRECT IGNITION VALVE MODELS
Figure 29
1.To wire Junction Box Receptacle, remove the tab on the side of the receptacle (hot side) to split receptacle. This will be required to separate blower and valve circuits.
2.Power for switched and live sides of Duplex Receptacle must come from the same power source. (One circuit breaker on main panel must switch all power off.)
3.From the wall box to the fireplace a
4.Two wall switches, or a wall switch and thermostat may be used to activate the two receptacle plugs independently.
Page 34 |